Instruction Manual
D200354X012
4200 Transmitters
March 2011
7
CSA
Special Conditions of Safe Use
Intrinsically Safe, Explosion-proof, Dust Ignition-proof
No special conditions for safe use.
Table 5. Hazardous Area Classifications—CSA (Canada)
Certification
Body
Type
Certification Obtained
Entity Rating
Temperature Code
Enclosure Rating
CSA
4211, 4221
Intrinsically Safe
Class/Division
Class I,II,III Division 1 GP A,B,C,D,E,F,G
per drawing GE16020
Ui = 30 VDC
Ii = 150 mA
Pi = 1.0 W
Ci = 5 nF
Li = 0 mH
T4 (Tamb
v
71
°
C)
4X
4210, 4211,
4212, 4215,
4220, 4221,
4222
Explosion‐proof
Zone
Ex d IIC T5
Class/Division
Class I, Division 1 GP B,C,D T5
- - -
T5 (Tamb
v
71
°
C)
4X
4210, 4211,
4212, 4215,
4220, 4221,
4222
Class II Division 1 GP E,F,G T5
- - -
T5 (Tamb
v
71
°
C)
4X
FM
Special Conditions of Safe Use
Intrinsically Safe, Explosion-proof, Dust Ignition-proof, Non‐Incendive
No special conditions for safe use.
Table 6. Hazardous Area Classifications—FM (United States)
Certification
Body
Type
Certification Obtained
Entity Rating
Temperature Code
Enclosure Rating
FM
4211, 4221
Intrinsically Safe
Class/Division
Class I,II,III Division 1 GP A,B,C,D,E,F,G
per drawing GE16019
Vmax = 30 VDC
Imax = 150 mA
Pi = 1.0 W
Ci = 5 nF
Li = 0 mH
T4 (Tamb
v
71
°
C)
4X
4210, 4211,
4212, 4215,
4220, 4221,
4222
Explosion-proof
Zone
Class I Zone 1 AEx d IIC T5
Class/Division
Class I, Division 1 GP A,B,C,D T5
- - -
T5 (Tamb
v
71
°
C)
4X
4211, 4221
Class I Division 2 GP A,B,C,D T4
Class II Division 2 GP F,G T4
- - -
T4 (Tamb
v
71
°
C)
4X
4210, 4211,
4212, 4215,
4220, 4221,
4222
Class II Division 1 GP E,F,G T5
- - -
T5 (Tamb
v
71
°
C)
4X