WARNING
SHOCK HAZARD! Turn off
electrical power at circuit breaker,
use voltmeter or circuit tester to
ensure that POWER IS OFF.
Wiring Connections
Incoming power supply requires that:
• Ground wire is securely fastened to
panel as shown.
• 208-230V system use #8 AWG wire
from line disconnect switch and control
box.
• 460V system use #12 AWG wire from
line disconnect switch to control box.
1
The pump lead wires are connected to
"T1, T2 & T3" as shown below.
2
The grinder lead wires are connected
to "M1, M2 & M3" as shown below.
3
The pressure switch leads are con-
nected to the control panel as shown
below (black to black, brown to brown,
blue to blue).
4
The lead wire for the tank float switch
is connected to terminal connections 2
and 15 as shown below. This wire runs
along the length of the discharge line
to the tank.
5
The 5gpm solenoid valve lead wires
are connected to terminal 11 & 12 as
shown below.
6
The 2gpm solenoid valve lead wires are
connected to terminal 7 & 10 as shown
below.
Grind2Energy
™
System
Wiring Connections
Adjust
Power Supply
INPUT
N
N
DC ok
DC
ok
1 ON
0 OFF
2 2 2 4 4 4 7 10 11 12 15 M1 M2 M3 T1 T2 T3
L1
L2
L3
L1
L2
L3
GROUND
GROUND
GROUND
BLK BRN
BLU
BLU
TANK
FLUSH
START
STOP
WARNING
ELECTRICAL SHOCK HAZARD. DISCONNECT INCOMING POWER
BEFORE SERVICING CONTROL CENTER. FAILURE TO DO SO COULD
RESULT IN DEATH OR SERIOUS PERSONAL INJURY. DOOR
INTERLOCK SWITCHED DISCONNECT CONTROL CIRCUIT ONLY.
PRESS IF
JAMMED
Control Box
17
INCOMING
POWER
PUMP
GRINDER
FLOAT
SWITCH
2 GPM
SOLENOID
PRESSURE
SWITCH
5 GPM
SOLENOID
6
5
4
3
2
1