
1592009730 XW30-35VS GB r1.2 31.07.2015
XW30VS - XW35VS
4/4
11.
TECHNICAL DATA
Housing:
self extinguishing ABS.
Case:
facia 100x64 mm; depth 76mm
Mounting:
panel mounting in a 56x72 mm panel cut-out with two screws.
3x2mm. Distance between
the holes 40mm
Protection:
IP20.
Frontal protection:
IP65 with optional frontal gasket mod RGW-V (XW35VS).
Connections:
6,3mm faston heat-resistant wiring and/or 2,8mm for probes and d.i.
Power supply:
230Vac or. 110Vac
10%
Power absorption:
7VA max.
Display
: 3 digits, red LED, 14,2 mm high.
Inputs
: 2 NTC or PTC probe
Relay outputs:
Total current on loads MAX. 20A
compressor:
relay SPST 20(8) A, 250Vac or. SPST 8(3) A, 250Vac
light: :
relè SPST 16(6) A, 250Vac
fans:
relay SPST 8(3) A, 250Vac
Data storing
: on the non-volatile memory (EEPROM).
Kind of action:
1B.
Pollution grade:
normal
Software class:
A.
Operating temperature:
0÷60 °C.
Storage temperature:
-25÷60 °C.
Relative humidity:
20
85% (no condensing)
Measuring and regulation range:
PTC probe:
-50÷150°C (-58÷302°F)
NTC probe:
-40÷110°C (-58÷230°F)
Resolution:
0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C)
: ±0,5 °C ±1 digit
12.
CONNECTIONS
12.1
XW30VS
Lig
ht
Power supply: use terminal 3-4; according to the model 230Vac or 120Vac or 24Vac
12.2
XW35VS
Lig
ht
Power supply: use terminal 3-4; according to the model 230Vac or 120Vac or 24Vac
13.
DEFAULT SETTING VALUES
Label Name
Range
Default
Level
REGULATION
°C/°F
Set
Set point
LS÷US
3/37
Pr1
Hy
Differential
0,1÷25,5 °C / 1÷45°F
2/4
Pr1
LS
Minimum set point
-50,0°C÷SET / -
58°F÷SET
-10/14
Pr2
US
Maximum set point
SET ÷ 110°C / SET ÷
230°F
20/68
Pr2
OdS
Outputs activation delay at start up
0÷255 min.
0
Pr2
AC
Anti-short cycle delay
0÷30 min.
1
Pr1
CCt
Compressor ON time during fast freezing
0 ÷ 23h 50 min.
0.0
Pr2
COn
Compressor ON time with faulty probe
0÷255 min.
15
Pr2
COF
Compressor OFF time with faulty probe
0÷255 min.
30
Pr2
CH
Type of regulation
CL, Ht
CL
Pr2
DISPLAY
CF
Temperature measurement unit
°C ÷ °F
°C/F
Pr2
rES
Resolution (integer/decimal point)
in ÷ de
dE/-
Pr1
Lod
Local display
P1 ÷ 1r2
P1
Pr2
DEFROST
EdF
Defrost mode
In, Sd
in
Pr2
IdF
Interval between defrost cycles
1÷120h
8
Pr1
MdF
(Maximum) length for 1° defrost
0÷255 min.
20
Pr1
dFd
Displaying during defrost
rt, it, SEt, dEF, dEG
it
Pr2
dAd
MAX display delay after defrost
0÷255 min.
30
Pr2
dPO
First defrost after start up
n ÷ y
n
Pr2
dAF
Defrost delay after fast freezing
0 ÷ 23h 50 min.
0.0
Pr2
FANS- only XW35VS
FnC
Fans operating mode
C-n, C-y, O-n, O-y
O-n
Pr2
Fnd
Fans delay after defrost
0÷255 min.
10
Pr2
ALARMS
ALC
Temperature alarms configuration
rE÷Ab
Ab
Pr2
ALU
MAXIMUM temperature alarm
-50,0÷110°C/ -58÷230°F 110/230
Pr1
ALL
minimum temperature alarm
-50,0÷110°C/ -58÷230°F -40/-40
Pr1
AFH
Temperature alarm differential
0,1÷25,5 °C / 1÷45°F
2/4
Pr2
ALd
Temperature alarm delay
0÷255 min.
15
Pr2
dAO
Delay of temperature alarm at start up
0 ÷ 23h 50 min.
1,3
Pr2
EdA
Alarm delay at the end of defrost
0÷255 min.
30
Pr2
dot
Delay of temperat. alarm after closing the
door
0÷255 min.
15
Pr2
dOA
Open door alarm delay
0÷255 min.
15
Pr2
nPS
Pressure switch number
0÷15
0
Pr2
ANALOGUE INPUTS
Ot
Thermostat probe calibration
-12,0÷12,0°C / -21÷21°F
0/0
Pr2
O3
Display probe calibration
-12,0÷12,0°C / -21÷21°F
0/0
Pr2
P3P
Display probe presence
n ÷ y
n
Pr2
HES
Temperature increasing during the Energy
Saving cycle
-30÷30°F/-54÷54°F
0
Pr2
DIGITAL INPUTS
Odc
Open door control
no, Fan, CPr, F_C
no
Pr2
I2P
Configurable digital input polarity
CL÷OP
cL
Pr2
i2F
Digital input configuration
dor, EAL, bAL, PAL, dFr,
AUS, ES, OnF
dor
Pr2
dId
Digital input alarm delay
0÷255 min.
5
Pr2
OTHER
Adr
Serial address
0÷247
1
Pr2
Pbc
Kind of probe
PbC, ntc
ntc/Ptc
Pr2
rEL
Software release
- - -
2.0
Pr2
Ptb
Map code
- - -
- - -
Pr2
Prd
Probes display
Pb1
- - -
Pr2
Pr2
Access parameter list
- - -
- - -
Pr1