102
Digitax ST User Guide
Issue: 5
Easy saving and reading
Figure 10-2 Basic SMARTCARD operation
The SMARTCARD has 999 individual data block locations. Each
individual location from 1 to 499 can be used to store data until the
capacity of the SMARTCARD is used. The drive can support
SMARTCARDs with a capacity of between 4kB and 512kB.
The data block locations of the SMARTCARD are arranged to have the
following usage:
Table 10-1 SMARTCARD data blocks
‘Differences from default‘ parameter sets will be much smaller than
whole parameter sets and thus take up a lot less memory as most
applications only require a few parameters to be changed from the
default setting.
The whole card may be protected from writing or erasing by setting the
read-only flag as detailed section 10.2.10
clearing the SMARTCARD read only flag
Data transfer to or from the SMARTCARD is indicated by one the
following:
•
Digitax ST: The decimal point after the fourth digit in the upper
display will flash.
•
SM-Keypad Plus: The symbol 'CC' will appear in the lower left hand
corner of the display
The card should not be removed during data transfer, as the drive will
produce a trip. If this occurs then either the transfer should be
reattempted or in the case of a card to drive transfer, default parameters
should be loaded.
10.2 Transferring data
Data transfer, erasing and protecting the information is performed by
entering a code in Pr
xx.00
and then resetting the drive as shown in
Table 10-2 SMARTCARD codes
Where yyy indicates the block number 001 to 999. See Table 10-1 for
restrictions on block numbers.
N
If the read only flag is set then only codes 6yyy or 9777 are effective.
10.2.1 Writing to the SMARTCARD
3yyy - Transfer data to the SMARTCARD
The data block contains the complete parameter data from the drive, i.e.
all user save (US) parameters except parameters with the NC coding bit
set. Power-down save (PS) parameters are not transferred to the
SMARTCARD.
Pr 0.30 = rEAd +
Pr 0.30 = Prog +
Pr 0.30 = Auto +
Pr 0.30 = boot +
Auto
Save
Boot
Auto Save
Drive reads all
parameters from
the SMARTCARD
Drive automatically
writes to the
SMARTCARD
when a parameter
save is performed
Programs all drive
parameters to the
SMARTCARD
Drive boots from the
SMARTCARD on
power up and
automatically writes
to the SMARTCARD
when a parameter
save is performed
NOTE
Overwrites any
data already in
data block 1
Data Block
Type
Example Use
1 to 499
Read / Write
Application set ups
500 to 999
Read Only
Macros
Code
Action
2001
Transfer drive parameters as difference from defaults to a
bootable SMARTCARD block in data block number 001
3yyy Transfer drive parameters to a SMARTCARD block number yyy
4yyy
Transfer drive data as difference from defaults to SMARTCARD
block number yyy
5yyy
Transfer drive Onboard PLC program to SMARTCARD block
number yyy
6yyy Transfer SMARTCARD data block yyy to the drive
7yyy Erase SMARTCARD data block yyy
8yyy Compare drive parameters with block yyy
9555 Clear SMARTCARD warning suppression flag
9666 Set SMARTCARD warning suppression flag
9777 Clear SMARTCARD read-only flag
9888 Set SMARTCARD read-only flag
9999 Erase SMARTCARD
NOTE
Содержание Digitax ST
Страница 1: ...User Guide AC variable speed drive for servo motors Part Number 0475 0001 05 Issue 5 ...
Страница 209: ......
Страница 210: ...0475 0001 05 ...