PROGRAMMING TIPS:
• If you don’t want to program a particular day, you can skip it. Press
NEXT
one or more times until you
reach the desired day.
• If you want to similarly program days in a group with only slight differences, program as a group first, then
program individual days as needed. The individual day program overrides the group program.
• While programming the heating or cooling schedule, press the
GO TO HEAT
or
GO TO COOL
button
(choose for current schedule being programmed) to save any changes made and display the program
schedule for that mode of operation.
Step 4: Temporary Versus Permanent Hold
A temporary hold can be set when operating in any mode except for
OFF
. A temporary hold is set by pressing the
or
on the thermostat to adjust the desired temperature. The SET AT indication of the temperature setpoint
will change to HOLD AT and a message will be cycled in the thermostat messaging display area to confirm that a
temporary hold is set. A temporary hold setpoint will then be maintained until the start of the next programmed
time period or the
RUN
soft key is pressed.
A permanent hold can be set when operating in any mode except for
OFF
. To set a permanent hold, change
the temperature just like setting a temporary hold. When the desired setpoint is entered, the user will have
approximately 4 seconds to press the
PERM HOLD
soft key to convert the temporary hold into a permanent hold.
The SET AT by the setpoint will change to HOLD AT and a message will be cycled in the thermostat messaging
display area to confirm that a permanent hold is set. If the
PERM HOLD
soft key is not pressed within 4 seconds,
the hold will remain a temporary hold and the soft key will change to a
RUN
soft key.
A permanent hold setpoint will override the programmed setpoints and time periods and can only be ended by
pressing the
RUN
soft key.