background image

2

Safety Instructions

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK,
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a. Use this unit only in a manner intended by the

manufacturer.  If you have questions, contact the
manufacturer.

b. Before servicing or cleaning unit, switch power off

at service panel and lock service panel
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a warning device, such as a tag, to the
service panel.

WARNING

!

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned

off at the fuse box before wiring, and do not operate
fan without blades.

2. All wiring must be in accordance with the National

Electrical Code “ANSI/NFPA 70-2014” and Local
Electrical Codes. Use the National Electrical Code if
Local Codes do not exist. The ceiling fan must be
grounded as a precaution against possible electrical
shock. Electrical installation should be made or
approved by a licensed electrician.

3. The outlet box and joist must be securely mounted

and capable of reliably supporting at least 50 pounds.
Use only U.L. outlet boxes listed as “Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less”, and use the
mounting screws provided with the outlet box. Most
outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may
need to be replaced. Consult a qualified electrician if
in doubt.

4. The downrod furnished with the fan provides the

minimum recommended floor to fan blade clearance
for an 8 foot ceiling.

5. The fan must be mounted with the fan blades at least

7 feet from the floor to prevent accidental contact with
the fan blades.

6. Follow the recommended instructions for the proper

method of wiring your ceiling fan. If you do not know
enough about electrical wiring, have your fan installed
by a licensed electrician.

WARNING: 

To reduce the risk of electrical shock, this

fan must be installed with an isolating wall
control/switch.

NOTE:

This fan is suitable for use with solid-state speed

controls.

WARNING:

To avoid fire, shock or injury, do not use an

Emerson or any other brand of control not specifically
approved for this fan.

WARNING:

This product is designed to use only those

parts supplied with this product and/or any accessories
designated specifically for use this product by Emerson
Electric Co. Substitution of parts or accessories not
designated for use with this product by Emerson could
result in personal injury or property damage.

WARNING: 

To reduce the risk of personal injury, do not

bend the blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.

NOTE:

All setscrews must be checked and re-tightened

where necessary before installation.

1. Read your owner’s manual carefully and keep it for

future reference.

2. Be careful of the fan and blades when cleaning,

painting, or working near the fan. Always turn off the
power to the ceiling fan before servicing.

3. Do not put anything into the fan blades while they are

turning.

4. Do not operate reversing switch until fan blades have

come to a complete stop.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record

this data above and keep it in a safe place for future use.

U.L. Model No.:  CF4801 and CF4501

READ AND SAVE THESE INSTRUCTIONS

Table of Contents

Section

Page

Safety Instructions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1. Unpacking Instructions   . . . . . . . . . . . . . . . . . . . . . . . . .3-4
2. Electrical Requirements    . . . . . . . . . . . . . . . . . . . . . . . . . .4
3. Ceiling Fan Assembly    . . . . . . . . . . . . . . . . . . . . . . . . . .5-7
4. How to Hang Your Ceiling Fan    . . . . . . . . . . . . . . . . . . . .8
5. How to Wire Your Ceiling Fan  . . . . . . . . . . . . . . . . . . . . . .9
6. Final Assembly   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
7. Using Your Ceiling Fan   . . . . . . . . . . . . . . . . . . . . . . . . . .10

Section

Page

8. Attaching Optional Light Kit   . . . . . . . . . . . . . . . . . . . . . . .11
9.   Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
10. Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
11. Repair Parts   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
12. Crown Select Repair Parts   . . . . . . . . . . . . . . . . . . . . . .13
13. Premium Select Repair Parts   . . . . . . . . . . . . . . . . .14-15
14. Trouble Shooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Ceiling Fan Limited Warranty   . . . . . . . . . . . . . . . . . . . . . . .19

Содержание CROWN SELECT CF4501AP00

Страница 1: ...ssing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Net Weight 23 8 Lbs Model Numbers CROWN SELECT Model Numbers Fan Blades Not Included CF4801AB00 CF4801AP00 CF4801BS00 CF4801GBZ00 CF4801GES00 CF4801ORB00 CF4801SW00 CF4801VNB00 CF4801WW00 CF4501AP00 CF4501GBZ00 CF4501GES00 CF4501VNB00 ...

Страница 2: ...e your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only t...

Страница 3: ...ur local retailer or catalog outlet for replacement before proceeding 2 Remove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly 3 Remove the fan motor assembly from the protective plastic bag Place all carton contents on a protective surface A B D C F E G H PACKAGE CONTENTS 5 15 1 2 3 4 11 10 9 8 7 6 12 13 14 16 HARDWARE CONTENTS Part Descriptio...

Страница 4: ...nts Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may n...

Страница 5: ... through the holes in the motor coupling and the holes in the downrod Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed DOWN...

Страница 6: ...e motor coupling cover and motor 8 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the top Figure 5 9 Reinstall the hanger ball on the downrod as follows Route the motor leads through the hanger ball and slide the hanger ball over the downrod Figure 5 Install the pin through the holes at the top of the downrod and slide the hanger ball ...

Страница 7: ...nd install the five blade assemblies ordered separately in accordance with Step 13 13 Attach one blade assembly to the motor hub using two 10 32 x 18mm oval head screws supplied Figure 7 Do not tighten completely at this time Install remaining blade assemblies in the same way Gently snug all flange screws to the motor hub working around the hub in a clockwise sequence Next securely tighten all fla...

Страница 8: ... ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 9 WARNING 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 10 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was ju...

Страница 9: ...d hot wire using wire connector supplied After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black blue and yellow leads on the other side of the outlet box 5 How to Wire Your Ceiling Fan Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is...

Страница 10: ...g assembly Figure 14 2 Slide the large pendant onto the the speed control pull chain secure by connecting the coupling to the chain Slide the pendant onto the accent light pull chain secure by connecting the coupling to the chain Figure 15 3 Assembly of the ceiling fan is now complete Restore electrical power to the branch circuit at the fuse box or breaker panel 4 When controlled by a wall switch...

Страница 11: ...STRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish 10 Accessories This product is designed to use only those parts supplied with this product and or any accesso...

Страница 12: ...12 U L Model No CF4801 and CF4501 11 Repair Parts 6 13 1 2 3 16 14 15 7 10 20 19 24 18 17 5 4 23 27 12 11 29 30 25 26 31 18 28 32 11 12 33 22 8 21 9 ...

Страница 13: ... VNB 23 Motor 762508 762508 762508 762508 Parts Bag containing 764196 1 764196 1 764196 1 764196 1 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 18mm 11 20 Screw 8 32 x 3 8 2 21 Screw 10 24 x 14mm 21 22 Washer Flat 21 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capa...

Страница 14: ...764196 1 764196 1 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 18mm 11 20 Screw 8 32 x 3 8 2 21 Screw 10 24 x 14mm 21 22 Washer Flat 21 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capacitor 762242 762242 762242 762242 762242 25 Cover Switch Cup 760671 760671 19 760...

Страница 15: ... Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 18mm 11 20 Screw 8 32 x 3 8 2 21 Screw 10 24 x 14mm 21 22 Washer Flat 21 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capacitor 762242 762242 762242 762242 25 Cover Switch Cup 760671 25 760671 SW 760671 VNB 760671 2 26 Harness 761450 2 761450 8 761450 2 7...

Страница 16: ...housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 5 Screws holding blades to flanges are 5 Tighten screws securely loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise motor cover and tighten setscrew securely excessively 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball a...

Страница 17: ...17 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF4801 and CF4501 Notes ...

Страница 18: ...18 U L Model No CF4801 and CF4501 Notes ...

Страница 19: ...er this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when re...

Страница 20: ...e 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74470001 Form No BP7447 1 Revision 131113 U L Model No CF4801 and CF4501 Printed in China 11 13 ...

Отзывы: