Product Data Document

420DS-12A

October 1, 2007 - Page 2

Integrated Pump Control 

SCADA RTU

Website:  www.EmersonProcess.com/Remote

Remote Automation Solutions

Specifications

Well or Reservoir

Digital inputs:

Pump 1 status
Pump Remote/Local

Digital outputs:

Pump start
Pump Stop

Analog inputs:

Station flow

Well drawdown
Outlet pressure
Chlorine residual
Clearwell level or tank level

Analog outputs:

VFD speed control 
Chemical feed pump

Counter inputs:

Station flow

Rain gauge

Duplex Booster or Lift Station

Digital inputs:

Pump 1 & 2 status
Pump 1 & 2 Remote/Local
2 tank level DI
Intrusion or Motion

Digital outputs:

Pump 1 & 2 start
Pump 1 & 2 Stop

Analog inputs:

Station flow

Inlet pressure
Outlet pressure
Chlorine residual
Clearwell level or tank level

Analog outputs:

VFD speed control 
Chemical feed pump

Counter inputs:

Station flow

Rain gauge

Triplex Booster or Lift Station

Digital inputs:

Pump 1, 2 & 3 status
Pump 1, 2 & 3 Remote/Local
2 tank level DI
Intrusion or Motion 

Digital outputs:

Pump 1, 2 & 3 start
Pump 1, 2 & 3 Stop

Analog inputs:

Station flow

Inlet pressure
Outlet pressure
Chlorine residual
Clearwell level or tank level

Analog outputs:

VFD speed control 
Chemical feed pump

Counter inputs:

Station flow

Rain gauge

ControlWave ExpressPAC  

SCADA Package

ControlWave MIcro  

PLC/RTU

ControlWave MIcro  

PLC/RTU SCADA Package

Содержание Control Wave SCADA RTU

Страница 1: ...o maintain level pressure and or flow Some sites may also have the need to control chemical feed measure rain level and detect intrusion events All of these are pre programmed and available for use to customize for the specific site When the application requires modifications or addi tions to the standard program Bristol ControlWave Designer allows unlimited customization by your engineering staff...

Страница 2: ... 2 tank level DI Intrusion or Motion Digital outputs Pump 1 2 start Pump 1 2 Stop Analog inputs Station flow Inlet pressure Outlet pressure Chlorine residual Clearwell level or tank level Analog outputs VFD speed control Chemical feed pump Counter inputs Station flow Rain gauge Triplex Booster or Lift Station Digital inputs Pump 1 2 3 status Pump 1 2 3 Remote Local 2 tank level DI Intrusion or Mot...

Страница 3: ...icantly benefiting radio and cellular network architectures Daily Archive Stores 35 days of time stamped minimums maxi mums averages and totals Hourly Archive Stores hourly time stamped minimums maximums averages and totals Trend Archive The Trend Archive stores instantaneous values at a fixed period from one minute to sixty minutes Setup and Configuration As mentioned earlier the ControlWave pump...

Страница 4: ... taneous values of pressure flow and level Setup and configuration may also be performed from the integral display keypad on the ControlWave PLC RTU SCADA package or via the SCADA system host HMI All configuration parameters are made available to OPC servers for compatibility with our OpenEnterprise SCADA software as well as third party SCADA software packages The configuration pages allow you to ...

Страница 5: ...nsducers Tank and wet well level measurement 5 to 700 feet 05 to 1 full scale accuracy Non fouling diaphragm options for lift station applications 4 20 mA or 0 5 V output AquaSensors Water Quality Instruments The AquaSensors DataStick provides a cost ef fective plug and play analytical measurement sys tem for continuous use in industrial environments DataStick communicates with ControlWave via a p...

Страница 6: ...prove the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchaser and end user OpenEnterprise SCADA Host T...

Отзывы: