background image

3

This Manual is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Do not install or use fan if any part is
damaged or missing. Call Toll-Free:

1-800-654-3545

!

WARNING

This product is designed to use only
those parts supplied with this product
and/or any accessories designated
specifically for use with this product by
Emerson Electric Co. Substitution of
parts or accessories not designated for
use with this product by Emerson Electric
Co. could result in personal injury or
property damage.

!

WARNING

Tools Needed for Assembly

One Phillips head screwdriver
One wire stripper
One stepladder
Two 60-watt candelabra base bulbs
(not supplied)

Materials

Wiring, outlet box and box connectors
must be of type required by the local code.
The minimum wire would be a 3-conductor
(2-wire with ground) of the following sizes:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

Before assembling your ceiling fan, refer
to the section on proper method of wiring
your fan (Page 11). If you feel you do not
have enough wiring knowledge or
experience, have your fan installed by a
licensed electrician.

!

WARNING

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each
step is completed, place a check mark in the box. This will insure that all steps
have been completed and will be helpful in finding your place should you be
interrupted.

NOTE: If you are uncertain of part
description, refer to exploded view
illustration.

a. Fan motor assembly
b. One coupling cover
c. One ceiling cover
d. Five fan blades
e. Five blade flanges
f. One light kit assembly
g. One hanger bracket
h. One hanger ball/6” downrod assembly
i. One glass shade
j. One fan/light wall control

(transmitter and receiver)

k. One loose parts bag containing:

1. One clevis pin
2. One hairpin clip
3. Five wire connectors
4. Two #8-32 x 1-1/4” threaded studs

(ceiling cover)

5. Two #8 external tooth lockwashers

(ceiling cover)

6. Two #8-32 knurled knobs

(ceiling cover)

7. Sixteen #10-32 x 5/16” pan head

blade screws

8. Sixteen #10 flat blade washers
9. Eleven #8-32 x 1-1/4” oval head

screws

10. Four #8-32 x 1/4” pan head screws

(light kit assembly)

1. Open carton containing fan. Remove

top half of styrofoam unit. Remove
parts and check to see that you have
received the following parts:

BP7335 Palazzo  1/9/07  9:05 AM  Page 3

Содержание CF704SAB03

Страница 1: ...o F40BP73350000 Form No BP7335 ETL Model No CF943 READ AND SAVE THESE INSTRUCTIONS Net Weight 37 9 Lbs PALAZZO 54 Ceiling Fan Owner s Manual CF943AGW00 CF943BZH00 Model No BP7335 Palazzo 1 9 07 9 05 AM Page 1 ...

Страница 2: ...iably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 50 Lbs or Less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum...

Страница 3: ...wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE If you are uncertain of part descriptio...

Страница 4: ... D FAN BLADES EMERSON HI MED LOW FAN OFF LIGHT ON OFF H HANGER BALL 6 DOWNROD ASSEMBLY A FAN MOTOR ASSEMBLY B COUPLING COVER F LIGHT FITTER ASSEMBLY K LOOSE PARTS BAG I GLASS SHADE J FAN LIGHT WALL CONTROL E BLADE FLANGES C CEILING COVER NOTE Place the parts from the loose parts bags in a small container to keep them from being lost CARDBOARD SHIPPING RETAINER 2 PROTECTIVE PLASTIC BAG IMPORTANT IM...

Страница 5: ...ing cover This system allows you to regulate your ceiling fan speed and light intensity NOTE An optional Emerson Electric SW110 Remote Control may also be used to control your ceiling fan To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 50 Lbs or Less and use screws supplied with outlet box Most outlet boxes commonly used for...

Страница 6: ... and screws from existing switches Pull switches out from wall boxes and determine which wall box contains the hot lead and which wall box contains the load wire Also identify traveler wires which are common to both wall boxes Disconnect wires from existing switches only Do not attempt to disconnect any wires not already connected to existing switches 3 Before installing wall control place wall co...

Страница 7: ...til fan installation is completed 10 Refer to How to Assemble Your Ceiling Fan section to complete the assembly of your ceiling fan HOT BLACK FAN LIGHT WALL CONTROL TRAVELER WIRE BLK BLK LOAD BLACK GROUND NEUTRAL REMOTE CONTROL RECEIVER LOCATED WITHIN THE CEILING COVER EMERSON EMERSON HI MED LOW FAN OFF LIGHT ON OFF HI MED LOW FAN OFF LIGHT ON OFF Figure 4 7 STANDARD WIRING FOR EXISTING 3 WAY CONT...

Страница 8: ...LY Figure 10 WARNING To avoid possible fire or shock make sure that the wires are not pinched between the light fitter assembly and the light kit adapter plate Pinched wires will also cause the light fitter assembly to mount crooked on the light kit adapter plate 10 32 x 5 16 PAN HEAD BLADE SCREW 3 per blade 10 FLAT BLADE WASHER 3 per blade FAN BLADE BLADE FLANGE Figure 6 NOTE Take care not to scr...

Страница 9: ...are supplied in loose parts bag The clevis pin must go through the holes in the motor coupling and the holes in the downrod Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to m...

Страница 10: ...is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed as shown in Figure 12 could result in the fan falling WARNING How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 17 WARNING The outlet box and joist must be securely...

Страница 11: ...e to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX NOTE CEILING COVER SUPPL Y WIRES AND FAN WIRES OMITTED FOR CLARITY OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY Figure 18 Figure 19 2 Careful...

Страница 12: ...d in the loose parts bag into the tapped holes in the hanger bracket Figure 22 12 OUTLET BOX BLACK SUPPLY WIRE BLACK WHITE RECEIVER WIRE BLACK FAN WIRE BLUE FAN WIRE BLUE RECEIVER WIRE CAP THE YELLOW RECEIVER WIRE USING A WIRE CONNECTOR CEILING COVER WHITE RECEIVER WIRE WHITE FAN WIRE WIRE CONNECTOR RECEIVER WHITE SUPPLY WIRE SUPPLY GROUND WIRE GREEN OR BARE HANGER BALL GROUND WIRE GREEN HANGER BR...

Страница 13: ...the candelabra base bulbs 1 Install two 60W maximum candelabra base bulbs not supplied in the sockets of the light fitter assembly Figure 24 2 Unscrew the decorative finial nut and threaded washer from the light fitter assembly threaded stud Figure 24 3 Slide the glass shade onto the threaded stud until the glass rest against the light fitter assembly Figure 25 4 Thread the previously removed thre...

Страница 14: ...he Fan Light Wall Control is in the ON position 2 To set the desired fan speed press the HI MED or LOW buttons to operate your fan on high medium or low speed Figure 26 3 To turn your fan off press the OFF button 4 To set the level of light brightness press and hold the LIGHT button The light brightness will continue to increase then decrease while the button is held down When the light is at the ...

Страница 15: ... interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits for a Class ...

Страница 16: ...ied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only mainten...

Страница 17: ...ned off 4 Loose screws in motor housing 4 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrews in motor coupling is 1 Raise coupling cover and excessively not tightened securely tighten setscrews securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blade 3 Check ...

Страница 18: ...al be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 18 BP7335 Palazzo 1 9 07 9 05 AM Page 18 ...

Страница 19: ... Oval Head Flange 11 13 Screw 8 32 x 1 4 Pan Head 4 14 Cover Ceiling 763210 AGW 763210 BZH 15 Cover Coupling 763211 AGW 763211 BZH 16 Fan Housing Assembly 17 Flange Assembly full set for one fan 763215 AGW 763215 BZH 18 Blade Set full set for one fan 763217 AGW 763217 DC 19 Light Fitter Assembly 763220 BQ 763220 BQ 20 Harness Wiring with Reverse Module 763264 763264 21 Glass Shade 763222 AMT 76322...

Страница 20: ...l 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The lower glass of your ceiling fan i...

Отзывы: