background image

28

                                                                                                                                                                                                                            

ETL Model No.: CF5200

16. Troubleshooting

                                                                                            

          TROUBLE                                PROBABLE CAUSE                                                            SUGGESTED REMEDY

  

1. Fan will not start.

     1. Loose power line connections to the fan,               1. Check line wire connections to fan and switch 

                                            or loose switch wire connections in the                      wire connections in the switch housing assembly.

                                        

   switch housing assembly.

                                          

WARNING:

Make sure main power is turned OFF.

  

2. Fan sounds noisy.

      1. Blades not attached to fan.                                     1. Attach blades to fan before operating.

                                        2. Wire connectors inside switch housing                  2. Check to make sure wire connectors in switch
                                            assembly are rattling.                                                  housing assembly are not rattling against each other or
                                                                                                                                 against the interior wall of the switch housing assembly.

                                                                                                                                 

WARNING:

Make sure main power is turned OFF.

                                        3. Screws holding blade/flange assembly                  3. Tighten screws securely.
                                            to motor hub are loose.

  

3. Fan wobbles

           1. Phillips head set screws in motor coupler              1. Tighten both Phillips head set screws securely in the 

     

excessively.

                are loose.                                                                     motor coupler.

                                        2. Phillips head set screw in hanger ball/                   2. Tighten the Phillips head set screw in the 
                                            downrod assembly is loose.                                       hanger ball/downrod assembly.

                                        3. Screws securing fan blades to                               3. Check to be sure screws which attach the fan blades 
                                            motor hub are loose.                                                   to the motor hub are tight.

                                        4. Hanger bracket and/or ceiling outlet                      4. Tighten the hanger bracket screws to the outlet box,
                                        box is not securely fastened.                                          and/or secure outlet box.

      WARNING: 

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE

TROUBLESHOOTING YOUR FAN.

!

!

!

INSTRUCTION TO THE USER (if device contains a digital device)

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of
the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  in  a
residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to  radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules.
In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation
with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The
user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could
void the user’s authority to operate this equipment.

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

BP7511-1 CF5200 Penbrooke Select Eco.qxp_ BP7511  2/8/16  12:02 PM  Page 28

Содержание CF5200BS00

Страница 1: ...ubbed Bronze CF5200SW00 Satin White Model Numbers Net Weight 21 2 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com 44 54 60 or 72 Fan Blades Not Included TRANSITIONAL Español página 31 Français page 61 BP7511 1 CF5200 Penbrooke Select Eco qxp_ BP7511 2 8 16 12 02 PM Page 1 ...

Страница 2: ...itable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage WARNING To reduce the risk of personal...

Страница 3: ...he top of the motor facing up The lower foam pad serves as a holder for the fan during assembly B C D H G A F I E PACKAGE CONTENTS Part Description Quantity A Fan Motor Housing Assembly 1 B Ceiling Cover 1 C Motor Coupler Cover 1 D Blade Flanges 5 E Hanger Bracket 1 F Hanger Ball 4 5 Downrod Assembly 1 G Switch Cup Adapter 1 H Switch Cup Assembly 1 I SW605 Wall Control 1 5 1 2 3 10 11 7 8 9 12 6 4...

Страница 4: ...upport and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING ...

Страница 5: ... 3 Rotate and align the downrod holes with all the holes in the motor coupler Figure 3 PHILLIPS HEAD SET SCREW LOOSENED HANGER BALL 4 5 DOWNROD PIN GREEN GROUND WIRE Figure 1 3 1 Remove the hanger ball by loosening the Phillips head set screw in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the pin from the downrod then remove the hanger ball Figure 1 Retain the pin ...

Страница 6: ...ing cover are both oriented correctly Figure 6 3 4 Align the clevis pin holes in the downrod with the holes in the motor coupler Install the clevis pin and secure with the hairpin clip Figure 4 The clevis pin must go through the holes in the motor coupler It is critical that the clevis pin in the motor coupler is properly installed and securely tightened Retighten the Phillips head screws to secur...

Страница 7: ...te the two motor leads through the hanger ball Figure 7 Reinstall the hanger ball on the downrod as follows Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Figure 7 Pull the hanger ball up tight against the pin and securely retighten the Phillips head screw in the hanger ball Figure 7 A loose Phillip...

Страница 8: ...d separately 10 24 x 12mm ROUND HEAD SCREW 4 per blade flange FLAT WASHER 4 per blade flange BLADE FLANGE Figure 10 3 10 NOTE Your ceiling fan will operate with the following Blade Select Blades Sold Separately B77 B78 B79 B90 B91 B92 B97 B100 B101 B102 B103 B107 B108 B109 G44 G54 G60 Mount the fan blade sold separately using the four 10 24 x 12mm round head screws and flat washers supplied in par...

Страница 9: ...htening the screw Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again NOTE Take care not to scratch fan housing when installing blades To reduce the risk of personal injury do not bend the blade flange when inst...

Страница 10: ... replaced Consult a qualified electrician if in doubt WARNING CEILING FLOOR AT LEAST 7 Figure 12 4 How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 12 WARNING 4 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 13 Hanger bracket must seat firmly against outlet box If the outlet b...

Страница 11: ...NG COVER SUPPL Y WIRES AND FAN WIRES OMITTED FOR CLARITY HANGER BRACKET HANGER BALL HANGER BALL GROOVE ANTI ROTATION TAB Figure 14 4 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 14 Be sure the groove in the ball is engaged with the anti rotation tab on the hanger bracket Figure 14 11 emersonfans com Please ...

Страница 12: ... 15 5 How to Wire Your Ceiling Fan To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those parts supplied with this product and or any accessories designated spec...

Страница 13: ...s into the outlet box with the white and green leads on one side of the outlet box and position the black lead on the other side of the outlet box Figure 18 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING 13 emersonfa...

Страница 14: ...and turn until studs protrude through the holes in the ceiling cover Figure 20 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 20 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 5 5 Screw the two threaded studs su...

Страница 15: ...otor hub by tightening the three switch housing screws Spare 6 32 x 3 8 round head screw with lockwasher supplied in parts bag 6 Final Assembly REMOVE ONE 6 32 x 3 8 ROUND HEAD SCREW WITH LOCKWASHER LOOSEN TWO 6 32 x 3 8 ROUND HEAD SCREW WITH LOCKWASHER MOTOR HUB Figure 21 6 1 Remove one 6 32 x 3 8 round head screw with lockwasher from the motor hub and retain for later use Figure 21 Loosen the ot...

Страница 16: ... the connector of the switch housing assembly with the motor hub connector Figure 23 Make sure the connector latch closes properly SWITCH HOUSING ASSEMBLY 6 32 x 3 8 FLAT HEAD SCREWS 3 Figure 24 6 4 Tuck all the wires and connectors into the switch housing adapter Align the three screw holes of the switch housing assembly Secure the switch housing assembly to the switch housing adapter using the t...

Страница 17: ...switch when the switch is turned OFF the control will remember the light intensity and fan speed When the switch is turned back ON the light and fan will resume operation as they were prior to the switch being turned OFF WALL CONTROL CODE SWITCHES ON 1 2 3 4 5 I CODE SWITCHES WALL CONTROL Figure 25 7 Wall Control Procedures 7 1 Your Emerson Ceiling Fan Light Control consists of wall mounted transm...

Страница 18: ... install the ceiling fan wall control into the outlet box 8 3 Remove faceplate and screws from existing wall control Pull control out from the wall box Determine the hot wire and the load wire and disconnect these wires from control Figure 27 Do not attempt to disconnect any wires not already connected to existing control 8 1 This control is designed to operate only one ceiling fan NOTE Electric c...

Страница 19: ... switch covers Choose the finish that best suits your needs and snap the cover onto the wall control Figure 28 8 9 Install decorator wall plate using the two screws provided with wall plate Leave wall control in OFF mode until fan installation is completed Figure 28 SW605 FAN LIGHT WALL CONTROL WALL BOX BLACK BLK HOT SWITCH COVER DECORATIVE WALL PLATE SCREWS 2 NEUTRAL WIRES TO 120VAC SOURCE T O LO...

Страница 20: ...ce wall control in OFF mode by pushing ON OFF switch to the OFF position 8 13 Install a wall control in the wall box containing the hot wire first Connect the black wire of the wall control to the hot wire Securely connect wires with wire connectors supplied 8 14 Connect one black wire of the wall control to both remaining traveler wires in the wall box and secure with wire connector supplied HOT ...

Страница 21: ...with wire connector supplied 8 19 Screw the SW605 wall control into wall boxes using the supplied screws Leave the SW605 wall control in OFF mode until fan installation is completed Figure 30 Check to see that all connections are tight and that no bare wires are visible at the wire connectors WARNING STANDARD WIRING FOR EXISTING 3 WAY CONTROLS HOT BLK TRAVELER WIRES BLACK LOAD EXISTING WALL CONTRO...

Страница 22: ...ul pairing the ceiling fan will automatically begin high speed conditioning of the motor During conditioning the electronic motor control software is calculating speeds for the 2nd through 5th speed settings based on the blades that were installed on the fan 9 2 The fan will run for approximately 1 minute in the upward direction then reverse direction to down flow and run an additional 1 minute Wh...

Страница 23: ...perating at any speed for the reverse button to function The blades will turn in the opposite direction and reverse the airflow 10 4 Your wall control comes complete with your choice of three wall cover plates ivory white or light almond 10 5 Your fan is now wired to be turned on and off from the fan switch 10 Using Your Ceiling Fan Fan installation must be completed including the installation of ...

Страница 24: ...tor assembly 2 pin connector Figure 32 AL100 ACCENT LIGHT HARNESS AL100 ACCENT LIGHT HARNESS CONNECTOR MOTOR ASSEMBLY 2 PIN CONNECTOR MOTOR ASSEMBLY Figure 32 11 2 Install the AL100 accent light to the motor assembly using three AL100 accent light mounting screws supplied with accent light Figure 33 AL100 ACCENT LIGHT HARNESS SCREW 3 MOTOR ASSEMBLY AL100 ACCENT LIGHT HARNESS Figure 33 11 3 Securel...

Страница 25: ...n and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 2 1 m above the floor and 46 cm from the walls If ceiling height allows install the fan 2 5 m 2 75 m above the floor for optimal airflow Consult your Emerson Retailer for optional mou...

Страница 26: ...el No CF5200 15 Repair Parts PARTS BAG 5 7 8 10 11 3 1 2 5 16 7 6 9 13 14 19 18 Not Supplied 10 21 22 11 23 20 8 24 17 9 15 13 14 4 6 12 12 BP7511 1 CF5200 Penbrooke Select Eco qxp_ BP7511 2 8 16 12 02 PM Page 26 ...

Страница 27: ...led 8 32 2 8 Pin Clevis 1 9 Clip Hairpin 1 10 Oval Head Screws 10 32 x 5 8 11 11 Flat Head Screws 6 32 x 3 8 4 12 Round Head Screw with Lockwasher 6 32 x 3 8 1 13 Round Head Screws 10 24 x 12mm 21 14 Flat Washers 10 21 15 Blade Balancing Kit 1 16 Ceiling Cover 1 764411 BS 764411 ORB 764411 SW 17 Motor Coupler Cover 1 764751 BS 764751 ORB 764751 SW 18 Fan Blades Sold Separately 19 Blade Flanges 5 7...

Страница 28: ...uipment has been tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful int...

Страница 29: ... 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Service If you call Emerson Customer Servi...

Страница 30: ...iday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EmErSON ElEctrIc cO 8100 W Florissant St louis mO 63136 Part No F40BP75110001 Form No BP7511 1 Revision 160204 ETL Model No CF5200 Printed in China 02 16 BP7511 1 CF5200 Penbrooke Select Eco qxp_ BP7511 2 8 16 12 02 PM Page 30 ...

Отзывы: