background image

13

U.L. Model No.: CF205

LIGHT KIT 
PLATE

LIGHT KIT 
COVER PLATE

FLAT AREA

LIGHT KIT PLATE 
SOCKETS REMOVED

Figure 24

5.

Place the cover plate onto the fan
motor/housing aligning the three flat
areas on the top flange of the cover
plate with the three pins on the inside of
the fan motor/housing (Figure 24).
Then turn the cover plate clockwise
until it stops turning.

6.

Your cover plate is now installed.

To avoid possible fire or shock, make
sure that the electrical wires are com-
pletely tucked inside the lower assembly
and not pinched by the cover plate.

!

WARNING

4.

Carefully tuck blue and white wires
from motor up into the fan motor/hous-
ing assembly (Figure 24).

Remote Control

Procedures

General

Your Emerson Ceiling Fan/Light Remote
Control consists of hand-held transmitter
and a receiver which is mounted under the
fan ceiling cover. The remote control is
designed to separately control your ceiling
fan speed and light intensity. There are
four push buttons   (

.

,

..

,

...

,

....

)  to set the

fan speed and turn the fan off. The light
(    ) push button turns the light on and off
and controls the light intensity. The blue
indicator light will illuminate while any but-
ton is pressed, indicating that the battery is
good.

The remote control transmitter is powered
by two AAA alkaline batteries (not includ-
ed). To prevent possible damage if the bat-
teries should leak, be sure to remove the
batteries when the control is not to be
used for an extended period of time.
Code switches in the transmitter may be
set in 32 different positions. If your fan and
light go on and off without using your con-
trol, you may be getting interference from
other remote units such as garage door
openers, car alarms or security systems.
To remedy this situations, simply change
the combination code in your transmitter.

Preset Memory Feature

Your Emerson receiver is equipped with a
preset memory feature. If the AC supply to
the receiver is powered through a wall
switch, when the switch is turned OFF, the
control will remember the light intensity
and fan speed. When the switch is turned
back ON the light and fan will resume
operation as they we re prior to the switch
being turned OFF.

Figure 25

Installation of Battery

1.

Remove the battery cover by pressing
firmly below the arrow and sliding the
cover off the control (Figure 25).

2.

Remove the connector from the battery
compartment and install two AAA alka-
line batteries.

CODE
SWITCHES

SR400 REMOTE 
CONTROL

BATTERY 
COMPARTMENT 
COVER

TWO AAA 
BATTERIES 

REMOTE CONTROL
LEVERS

ON

1

2

3

4 5

I

BP7375-1 Highpointe  8/19/10  2:50 PM  Page 13

Содержание CF205GES01

Страница 1: ...E INSTRUCTIONS Net Weight 22 1 Lbs HIGHPOINTE Ceiling Fan Owner s Manual Model Numbers CF205BS01 Brushed Nickel Finish with Opal Matte Glass and Dark Mahogany Blades CF205GES01 Golden Espresso with Sandstone Glass and Chocolate Blades BP7375 1 Highpointe 8 19 10 2 50 PM Page 1 ...

Страница 2: ...nce for a 9 foot ceiling The 6 downrod supplied must be used for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician CAU...

Страница 3: ...t in personal injury or property damage WARNING a Fan motor housing assembly b One ceiling cover c One coupling cover d Three fan blades e Three blade flanges f Nine decorative blade nuts bagged g One hanger bracket h One hanger ball 12 downrod assembly i One 6 downrod j One rod support assembly k Three decorative rod assemblies l Six decorative rod assembly screws bagged m One light kit plate n O...

Страница 4: ... the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceil ing fan must be properly grounded as a precaution against possible electri cal shock WARNING To avoid possible fire or shock fol low all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING If your...

Страница 5: ...ht kit and glass To assemble without the light kit and glass you will use the no light cover plate In order to use the no light cover plate the light sockets will need to be removed from the light kit plate CAUTION Before installing and tight ening the screws be sure there are no wires pinched between the light kit plate and the fan motor housing assembly NOTE In order to remove the light sockets ...

Страница 6: ...tscrews are properly installed as shown in Figure 9 could result in the fan falling WARNING U L Model No CF205 8 Unscrew the two upper setscrews Figure 8 until they clear the inside of the motor coupling Then separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes in the downrod with the holes in the motor coupling Install the ...

Страница 7: ...lled in the rod support assembly Then position the three screws in the rod support toward the top and slide the rod support over the downrod Figure 10 ROD SUPPORT ASSEMBLY MOTOR HOUSING GROMMET COUPLING COVER SCREWS 3 Toward Top Figure 10 12 Using the decorative rod screws sup plied attach the three decorative rod assemblies to the motor housing Figure 11 The decorative rods must be oriented so th...

Страница 8: ...oor to blades Figure 14 WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws sup plied with outlet box Most outlet boxes commonly used for support o...

Страница 9: ...d the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING If you feel that you do not have enough electrical wiring knowledge or experi ence have your fan installed by a licensed electrician 9 CAUTION To reduce the risk of electri cal shock disconnect the electrical supply circuit before installing the fan light kit or receiver 2 Carefully lift the fan a...

Страница 10: ...IRE FROM HANGER BRACKET RECEIVER RED WIRE RECEIVER WHITE WIRE FAN WHITE WIRE FAN BLACK WIRE ANTENNA AC IN N AC IN L FO R LI G HT TO M O TO R N RECEIVER BLUE WIRE RECEIVER BLACK WIRE RECEIVER WHITE WIRE SUPPLY WHITE WIRE NEUTRAL SUPPLY BLACK WIRE HOT GROUND WIRE GREEN GROUND WIRE FROM HANGER BALL FAN BLUE WIRE 1 1 4 THREADED STUD 2 T O M O T O R L Figure 17 10 U L Model No CF205 STANDARD ON OFF WAL...

Страница 11: ...p into the outlet box while inserting the receiv er fully into the hanger bracket Position the antenna wire on top of the receiver 4 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 19 5 Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover Figure 19 6 Secure the ceiling cover in place ...

Страница 12: ... wire of the light kit plate from the black wire of the fan motor housing assembly Disconnect the white wire of the light kit plate from the white wire of the fan motor housing assembly Figure 22 LIGHT KIT PLATE CUT LIGHT SOCKET WIRES CUT LIGHT SOCKET WIRES Figure 22 REASSEMBLE LIGHT KIT PLATE REASSEMBLE MOTOR SCREW 3 REMOVE SOCKET PLATE SCREWS 2 per plate REMOVE SOCKET SOCKET PLATE 2 Figure 23 Tu...

Страница 13: ...that the battery is good The remote control transmitter is powered by two AAA alkaline batteries not includ ed To prevent possible damage if the bat teries should leak be sure to remove the batteries when the control is not to be used for an extended period of time Code switches in the transmitter may be set in 32 different positions If your fan and light go on and off without using your con trol ...

Страница 14: ... Bracket A storage bracket is provided for holding your remote control when not in use Figure 26 If you desire to use the brack et install it on a wall that is away from excess heat or humidity 1 To set the desired fan speed hold the FAN button down then press one of the four buttons to oper ate your fan from low to high speeds 2 To turn the light on and off press the LIGHT button down then press ...

Страница 15: ...revent damage to finish Accessories 1 Downrod Extension Kits see store or catalog 2 Ceiling Fan Controls see store or catalog COUPLING COVER MOTOR HOUSING REVERSE SWITCH Figure 27 3 If airflow is desired in the opposite direction turn the fan off and wait for the blades to stop turning Then slide the coupling cover up push the revers ing switch in opposite direction Figure 27 Slide coupling cover ...

Страница 16: ...gainst each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Screws holding blades to 4 Tighten screws securely flanges are loose 5 Loose screws in motor housing 5 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is 1 Raise coupling cover and tighten excessively not tightened secur...

Страница 17: ...rect the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits for ...

Страница 18: ...U L Model No CF205 Repair Parts 3 2 1 5 4 26 14 15 6 7 17 17 16 18 9 23 11 28 27 8 25 13 10 20 19 22 24 21 22 12 18 BP7375 1 Highpointe 8 19 10 2 50 PM Page 18 ...

Страница 19: ...8 GES 19 Blade Set full set for one fan 763601 763601 1 20 Flange Set full set for one fan 763597 BS 763597 GES 21 Harness Assembly Wiring 763595 763595 22 Fitter Assembly Light 763603 BS 763603 GES 23 Glass Lower 763605 763605 1 24 Cover Plate 763609 BS 763609 GES 25 Bulb Halogen 50 watt Mini Candelabra Base 26 Downrod 6 761631 32 761631 44 27 Transmitter Wall Control SR401 764090 764090 28 Recei...

Страница 20: ...l 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of y...

Отзывы: