6
U.L. Model No.: CF784
3. Ceiling Fan Assembly
MOTOR HUB
BLADE/FLANGE
ASSEMBLY
1/4-20 x 14mm CAPTIVE
PAN HEAD SCREW
(2 per blade/flange assembly)
MOTOR HUB
NOTCHED AREA
Figure 4
3.4
NOTE: Take care not to scratch fan housing when
installing blades.
Loosely attach one blade/flange assembly to the motor
hub by securing the two 1/4-20 x 14mm captive pan head
screws. Make sure the screws are NOT tightened
(Figure 4).
Repeat this procedure for other four blade assemblies.
BLADE/FLANGE
ASSEMBLY
FLANGE
INTERLOCKING
FEATURE
FLANGE
INTERLOCKING
FEATURE
Figure 5
3.5
NOTE: Each blade/flange assembly must have the
flange gasket in place between each of the
assemblies.
The blade flanges have an interlocking feature that must
be fully engaged before tightening the screw.
Make sure all the flanges are properly engaged and then
tighten the flange screws (Figure 5).
If one of the flanges does not seat properly on the motor
hub, loosen the adjacent flange screws, re-engage and
reseat the flanges, then tighten the screws again.
To reduce the risk of personal injury, do not bend the
blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.
WARNING
!