13
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF784
LISTED WIRE
CONNECTOR
SUPPLY WHITE
(NEUTRAL)
FAN MOTOR
WHITE WIRE
Figure 22
5.2
Securely connect the fan motor white wire to the supply
white (neutral) wire using wire connector (supplied)
(Figure 22).
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
5.1
Connect the green grounding lead from the hanger ball
and the green grounding lead from the hanger bracket to
the grounding conductor of supply (this may be a bare
wire or wire with green colored insulation). Securely
connect wires with wire connectors (supplied) (Figure 21).
5. How to Wire Your Ceiling Fan
To avoid possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
WARNING
!
This product is designed to use only those parts supplied
with this product and/or any accessories designated
specifically for use with this product by Emerson Electric
Co. Substitution of parts or accessories not designated
for use with this product by Emerson Electric Co. could
result in personal injury or property damage.
WARNING
!
GROUND
CONDUCTOR SUPPLY
LISTED WIRE
CONNECTOR
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
Figure 21