button is held down. When the light is
at the desired brightness, release the
button.

5. To turn the light on and off, press and

release the       button. The light will turn
on at the light level previously set (see
step 4).

6. If airflow is desired in the opposite

direction, turn the fan off and wait for
the blades to stop turning. Then slide
the reversing switch (Figure 18) to the
opposite position and turn the fan on
again. The blades will turn in the oppo-
site direction and reverse the airflow.

REVERSING 
SWITCH

9. Grasp the lower ring assembly and

raise it up and over the ring rods of the
adapter assemlby (Figure 16). Position
the ring assembly of that the ring
assembly arms protrude through the
holes at the end of the ring rods.
Secure the ring asembly in the ring
rods using the six ring screws.

10. Your ceiling fan is now installed and

wired to be controlled by your remote
control system.

11

LOWER RING 
ASSEMBLY

RING
SCREWS (6)

RING ROD

ARM

Figure 16

Operating Your

Ceiling Fan

IMPORTANT

Fan installation must be completed,
including the installation of the fan
blades, before testing of the remote
control.

Your remote control (Figure 17) has full
control of your fan and light. However, air-
flow direction is controlled by a slide
switch on the switch housing.

1. Restore electrical power to the outlet

box by turning the electricity on at the
service panel.

2. To set the desired fan speed, press the

HI, MED, or LOW buttons to operate
your fan on high, medium, or low speed
(Figure 17).

3. To turn your fan off, press the OFF

button.

4. To set the level of light brightness,

press and hold the light       button. The
light brightness will continue to
increase then decrease while the

STORAGE
BRACKET

H

I

OFF

LOW

MED

Figure 17

Figure 18

Installation of

Storage Bracket

A storage bracket is supplied with the
remote control for holding the transmitter
when not in use. If you desire to use the
bracket, use the two screws (supplied)
and install it on a wall that is away from
excess heat or humidity.

U.L. Model No.: CF180

BP7357 CF180 BRIDGETON  9/19/07  11:21 AM  Page 11

Содержание BRIDGETON CF180AP00

Страница 1: ... AND SAVE THESE INSTRUCTIONS Net Weight 30 9 Lbs BRIDGETON Ceiling Fan Owner s Manual Model Numbers CF180AP00 Antique Pewter with Natural Cherry Mahogany Blades CF180GES00 Golden Espresso with Teak Natural Pine Blades BP7357 CF180 BRIDGETON 9 19 07 11 21 AM Page 1 ...

Страница 2: ... commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6...

Страница 3: ...esignated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING a Fan motor and housing assembly b One ceiling cover c One adapter light fitter assembly d Five fan blades e Five blade flanges f One hanger bracket g One hanger ball downrod assembly h One lower ring assembly with six ring screws attached i One lower glass j One remote control tra...

Страница 4: ... sections The first section REMOTE CONTROL PROCEDURES describes how to install the 9 volt alka line battery not supplied in the remote control transmitter and how to set the operating frequency of the transmitter and receiver These instructions must be performed prior to the installation of the ceiling fan as described in the second section CEILING FAN PROCE DURES REMOTE CONTROL PROCEDURES General...

Страница 5: ...st possible electri cal shock WARNING How to Assemble Your Ceiling Fan 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 2 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for rein stallation in step 5 2 Unscrew the two upper setscrews Figure 3 until they clear the inside of the motor ...

Страница 6: ...f the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING 6 The fan comes with blue blac...

Страница 7: ... HEAD SCREW WITH LOCKWASHER 2 BLADE FLANGE MOTOR HUB Figure 6 ADAPTER ASSEMBLY ADAPTER PLATE WHITE WIRES BLACK WIRES 8 32 x 12mm PAN HEAD SCREW 2 Figure 7 ADAPTER LIGHT FITTER ASSEMBLY TIGHTEN TWO SCREWS INSTALL ONE 8 32 x 12mm PAN HEAD SCREW Figure 8 11 Connect the white wire from the light fitter to the white wire from the motor Figure 7 Connect the black wire from the light fitter to the black ...

Страница 8: ...support and may need to be replaced Consult a qualified electri cian if in doubt WARNING CEILING AT LEAST 7 FLOOR Figure 9 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 10 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not...

Страница 9: ...nnectors except for the ground wire 2 Refer to Figure 12 and 13 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiver white ...

Страница 10: ...ER BALL AND HANGER BRACKET TWO CONDUCTOR CABLE WITH GROUND BLACK HOT WHITE GROUND TO 120 VOLT SUPPLY WHITE BLUE WHITE BLUE Figure 13 3 Push the wires and connectors up into the outlet box while inserting the receiv er fully into the hanger bracket Position the antenna wire on top of the receiver 4 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 12 5 L...

Страница 11: ...EWS 6 RING ROD ARM Figure 16 Operating Your Ceiling Fan IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your remote control Figure 17 has full control of your fan and light However air flow direction is controlled by a slide switch on the switch housing 1 Restore electrical power to the outlet box by turning the electri...

Страница 12: ...in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception whic...

Страница 13: ...t the interior wall of the switch housing WARNING Make sure main power is turned off 4 Screws holding blades to 4 Tighten screws securely flanges are loose 5 Loose screws in motor housing 5 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is 1 Raise coupling cover and tighten excessively not tightened securely setscrew securely 2 Set...

Страница 14: ...14 Repair Parts 10 16 12 3 2 1 5 4 7 6 14 21 19 23 HI OFF LOW MED 24 11 15 13 9 17 20 25 8 22 18 U L Model No CF180 BP7357 CF180 BRIDGETON 9 19 07 11 21 AM Page 14 ...

Страница 15: ... Wiring 762729 762729 18 Adapter Light Fitter 762730 AP 762730 GES 19 Rod Ring Assembly 6 762735 AP 762735 GES 20 Fitter Light 763207 763207 21 Glass Lower 762733 762733 22 Ring Assembly Lower 762734 AP 762734 GES 23 Screw Ring 6 762736 AP 762736 GES 24 Transmitter Remote Control 761970 1 761970 1 25 Receiver Remote Control 762670 762670 Owner s Manual BP7357 1 BP7357 1 15 Repair Parts Listing Bef...

Страница 16: ...r authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emers...