26
100-412-196 REV. 06
4.1
Technical Specifications
4.1.1 Environmental Specifications
The LPX Power Supply has the following environmental specifications.
4.1.2 Electrical Specifications
The following tables list input voltage and current requirements for the LPX Power Supply.
Table 4.1
Environmental Specifications
Environmental Condition
Acceptable Range
Operating Temperature
+41° F to +122° F (+5° C to +40° C)
Storage Temperature
-13° F to +131° F (-25° C to +55° C) (short time
exposure not to 158° F (70° C) in 24
hours)
Relative Humidity
Maximum 95%, non-condensing
Table 4.2
Input Voltage
Live Voltage
100 to 120 V @ 50/60Hz
200 to 240 V @ 50/60Hz
Table 4.3
Current Rating Fusing
Model
Power
Current Rating
20 kHz
150 W
2 Amp Max. @ 100 to 120 V / 10 Amp fuse
150 W
1 Amp Max. @ 200 to 240 V / 10 Amp fuse
550 W
9.5 Amp Max. @ 100 to 120 V / 10 Amp fuse
550 W
6 Amp Max. @ 200 to 240 V / 10 Amp fuse
30 kHz
550 W
9.5 Amp Max. @ 100 to 120 V / 10 Amp fuse
550 W
6 Amp Max. @ 200 to 240 V / 10 Amp fuse
40 kHz
150 W
2 Amp Max. @ 100 to 120 V / 10 Amp fuse
150 W
1 Amp Max. @ 200 to 240 V / 10 Amp fuse
550 W
9.5 Amp Max. @ 100 to 120 V / 10 Amp fuse
550 W
6 Amp Max. @ 200 to 240 V / 10 Amp fuse
Содержание Branson LPX
Страница 4: ...iv 100 412 196 REV 06 ...
Страница 6: ...vi 100 412 196 REV 06 ...
Страница 8: ...viii 100 412 196 REV 06 ...
Страница 10: ...x 100 412 196 REV 06 Table 7 2 System Trouble Analysis Chart 73 Table 7 3 Alarms Errors 76 ...
Страница 24: ...14 100 412 196 REV 06 ...
Страница 33: ...100 412 196 REV 06 23 Chapter 3 Delivery and Handling 3 1 Delivery and Handling 24 ...
Страница 38: ...28 100 412 196 REV 06 4 1 4 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Страница 76: ...66 100 412 196 REV 06 ...
Страница 85: ...100 412 196 REV 06 75 Figure 7 2 LPX Power Supply Interconnect Diagram ...