If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time
and remove the existing light fixture.

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with national and local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.

WARNING

!

Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.

WARNING

!

Electrical Requirements

IMPORTANT INSTALLATION INFORMATION

Your ceiling fan contains a built-in uplight assembly in the motor housing. The fan and
uplight may be controlled using one of the two following methods:

1. By an Emerson SR330 Remote Control or

SW350 Wall Control.

2. By any other Emerson Fan/Light Controls

or by Standard Wall Switches.

Because the procedures are widely different, they have been separated into different
sections. Determine how you are going to control your fan, then select the appropriate
Installation Section from the list below.

SECTION Title

Use

Page No.

1. Assembly Instructions for Installing

Section “A”

5

the CF2600 and CF2650 Ceiling Fan with 
the Emerson SR330 Remote Control or
the SW350 Wall Control

2. Assembly Instructions for Installing

Section “B”

10

the CF2600 and CF2650 Ceiling Fan 
Controlled by Emerson Fan/Light 
Controls (other than SR330 or SW350) 
or Standard Wall Switches

To avoid possible fire or shock, follow all wiring
instructions carefully. Any electrical work not
described in these instructions should be done or
approved by a licensed electrician.

WARNING

!

4

Содержание BP7251

Страница 1: ... return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Wh...

Страница 2: ...y U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceili...

Страница 3: ...insure that all steps have been completed and will be helpful in finding your place should you be interrupted 18 DOWNROD ROD ASSEMBLY 3 BLADE FLANGES ROD SUPPORT ASSEMBLY HANGER BALL DOWNROD ASSEMBLY YELLOW LEAD ASSEMBLY UPLIGHT LIGHT KIT PLATE ASSEMBLY FAN MOTOR HOUSING AND SHADE ASSEMBLY CEILING COVER LOOSE PARTS BAG HANGER BRACKET MOTOR COVER GLASS SHADE LIGHT KIT ADAPTER ASSEMBLY Installed Wir...

Страница 4: ...ed Consult a qualified electrician if in doubt WARNING Electrical Requirements IMPORTANT INSTALLATION INFORMATION Your ceiling fan contains a built in uplight assembly in the motor housing The fan and uplight may be controlled using one of the two following methods 1 By an Emerson SR330 Remote Control or SW350 Wall Control 2 By any other Emerson Fan Light Controls or by Standard Wall Switches Beca...

Страница 5: ...t 3 above the motor coupling Figure 3A Strip insulation 1 2 from end of the white and blue wires Install a wire connector on the black wire this wire will not be used 7 Using wiring connectors supplied connect the white blue and yellow wires from the downrod to the white blue and yellow wires from the fan motor Figure 4A and 6A Wires must be connected color to color 8 Remove the wire connectors fr...

Страница 6: ... the motor All wires and wire connectors must be enclosed under the motor cover NOTE Lightly snug the knurled knob and make sure the wires and wire connectors are completely inside the motor coupling cover and not pinched between the motor coupling cover and the motor 15 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the top Figure 9A ...

Страница 7: ...ecessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 2 Figure 12A TOP OF HOUSING CANDELABRA BASE LAMP SOCKET Figure 10A 19 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to...

Страница 8: ...the hole in the ceiling cover is clear of the downrod 29 Attach one blade assembly to the motor hub using two 10 32 x 5 8 oval head screws supplied Figure 17A Do not tighten completely at this time Install remaining blade assemblies in the same way Gently snug all flange screws to the motor hub working around the hub in a clockwise sequence Next securely tighten all flange screws again working in ...

Страница 9: ...rs in the raised center portion of the plate assembly Do not pinch wires between the light kit plate assembly and the adapter assembly 33 Secure the light kit plate assembly to the light kit adapter assembly by threading three 5 32 32 x 3 16 phillips head screws supplied into the threaded holes in the adapter assembly Figure 20A 9 LIGHT KIT ADAPTER ASSEMBLY JUMPER ASSEMBLY SETSCREW COLLAR Figure 1...

Страница 10: ...e 5 Separate untwist and unkink the three black white and blue motor wires then route the wires through the downrod 6 Using wiring connectors supplied connect the yellow uplight lead to the yellow wire from the downrod Figure 3B Fold the yellow wire into the slot in the motor coupling slide the downrod down the wires and seat the downrod in the motor coupling 7 Align the clevis pin holes in the do...

Страница 11: ...HOUSING CANDELABRA BASE LAMP SOCKET Figure 6B DOWNROD PIN HANGER BALL CEILING COVER Figure 5B IMPORTANT A If you have installed an 18 or longer downrod and are planning to install the decorative support rods assembly proceed to INSTALLATION OF DECORATIVE SUPPORT RODS ASSEMBLY on page 14 After you have installed the decorative support rods assembly continue with the following installation procedure...

Страница 12: ...hreaded studs and turn until studs protrude through the holes in the ceiling cover Figure 11B 18 Secure the ceiling cover in place by installing two lockwashers and two knurled knobs supplied Figure 11B Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 19 Use three 10 32 x 3 8 pan head screws and fla...

Страница 13: ...Figure 15B Connect the white wire from the plate assembly to the white wire form the motor shaft using a wire connector supplied NOTE When installing the light kit plate assembly position the wires and wire connectors in the raised center portion of the plate assembly Do not pinch wires between the light kit plate assembly and the adapter assembly 25 Secure the light kit plate assembly to the ligh...

Страница 14: ...od support assembly and loosely engage the rod hook with one of the rings on the support assembly Figure 3 Then tighten the setscrew using the 5 64 setscrew 5 Engage the other two support rods in the same manner as above Loosen the setscrew and raise the rod support assembly until the support rods are taut and in line with the downrod Figure 4 Then securely tighten the setscrew using the 5 64 hex ...

Страница 15: ...ire connections in the switch housing wire connections in the switch housing 2 Fan sounds noisy 1 Blades not attached to fan 1 Attach blades to fan before operating 2 Support rods loose 2 Tighten the barrels of the rod assemblies 3 Screws securing fan blade flanges to motor hub 3 Check to make sure the screws which attach are loose the fan flanges to the motor hub are tight WARNING Make sure main ...

Страница 16: ...er Motor 761621 3 761621 17 761621 21 761621 23 761621 17 761621 21 24 Screw 8 Washerhead 4 25 Capacitor 9 mfd 762117 762117 762117 762117 762117 762117 26 Motor 762304 762304 762304 762304 762304 762304 27 Hub Motor 760601 760601 760601 760601 760601 760601 28 Flange Set Full set for one fan 762105 762105 1 762105 2 762105 3 762105 1 762105 2 29 Adapter Assembly Light Kit 762094 762094 762094 762...

Отзывы: