Emerson BP7251 Скачать руководство пользователя страница 10

8. Install the setscrew (supplied) in the motor coupling

and tighten using the 5/32” setscrew wrench
(supplied) (Figure 3B).

9. Screw two 1” threaded studs (provided) into the

motor (Figure 4B). Leave approximately 7/8” of the
stud extending above the motor. Coil the wires and
wire connectors around the motor coupling, then
slide the motor cover over the downrod and rotate
the cover until the threaded studs protrude. Install
two lockwashers (supplied) and knurled knobs
(supplied) to secure the cover to the motor. All
wires and wire connectors must be enclosed under
the motor cover.

NOTE: Lightly snug the knurled knob and make
sure the wires and wire connectors are completely
inside the motor coupling cover and not pinched
between the motor coupling cover and the motor.

1. Position the motor housing and shade assembly in

the foam packing so that the top for the motor is
facing you.

2. Obtain the hanger ball/downrod assembly and

remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 1B). Remove the pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in Step 9.
Discard 4-1/2” downrod if using 18” or longer
downrod.

3. Push the yellow uplight lead connector through the

downrod (Figure 2B) until it extends about 6”.

4. Cut the yellow lead approximately 3” from the end

of the downrod (Figure 2B). Strip insulation 1/2”
from end of wire.

5. Separate, untwist and unkink the three black, white

and blue motor wires, then route the wires through
the downrod.

6. Using wiring connectors (supplied), connect the

yellow uplight lead to the yellow wire from the
downrod (Figure 3B). Fold the yellow wire into the
slot in the motor coupling, slide the downrod down
the wires and seat the downrod in the motor
coupling.

7. Align the clevis pin holes in the downrod with the

holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip (Figure 3B). The
clevis pin must go through the holes in the motor
coupling and the holes in the downrod. Push the
straight leg of the hairpin clip through the hole near
the end of the clevis pin until the curved portion of
the hairpin clip snaps around the clevis pin. The
hairpin clip must be properly installed to prevent
the clevis pin from working loose. 

10

SECTION B

Assembly Instructions for Installing the CF2600 and CF2650

Ceiling Fan Controlled by Emerson Fan/Light Controls

(other than SR330 or SW350) or Standard Wall Switches

HANGER BALL

PIN

DOWNROD

SETSCREW

Figure 1B

7/8"

1" THREADED STUD

MOTOR COVER

KNURLED KNOB

LOCKWASHER

MOTOR 

Figure 4B

DOWNROD

MOTOR COUPLING

CLEVIS
PIN

HAIRPIN
CLIP

CONNECT YELLOW 
WIRES USING WIRE 
CONNECTOR

SETSCREW

SETSCREW

CLEVIS PIN

MOTOR
COUPLING

DOWNROD

HAIRPIN
CLIP

Figure 3B

3"

DOWNROD

CUT HERE

YELLOW UPLIGHT 
LEAD

6"

CEILING
END

4-1/2" OR 18"

MOTOR 
END

Figure 2B

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed could result in the fan falling.

WARNING

!

Содержание BP7251

Страница 1: ... return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Wh...

Страница 2: ...y U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceili...

Страница 3: ...insure that all steps have been completed and will be helpful in finding your place should you be interrupted 18 DOWNROD ROD ASSEMBLY 3 BLADE FLANGES ROD SUPPORT ASSEMBLY HANGER BALL DOWNROD ASSEMBLY YELLOW LEAD ASSEMBLY UPLIGHT LIGHT KIT PLATE ASSEMBLY FAN MOTOR HOUSING AND SHADE ASSEMBLY CEILING COVER LOOSE PARTS BAG HANGER BRACKET MOTOR COVER GLASS SHADE LIGHT KIT ADAPTER ASSEMBLY Installed Wir...

Страница 4: ...ed Consult a qualified electrician if in doubt WARNING Electrical Requirements IMPORTANT INSTALLATION INFORMATION Your ceiling fan contains a built in uplight assembly in the motor housing The fan and uplight may be controlled using one of the two following methods 1 By an Emerson SR330 Remote Control or SW350 Wall Control 2 By any other Emerson Fan Light Controls or by Standard Wall Switches Beca...

Страница 5: ...t 3 above the motor coupling Figure 3A Strip insulation 1 2 from end of the white and blue wires Install a wire connector on the black wire this wire will not be used 7 Using wiring connectors supplied connect the white blue and yellow wires from the downrod to the white blue and yellow wires from the fan motor Figure 4A and 6A Wires must be connected color to color 8 Remove the wire connectors fr...

Страница 6: ... the motor All wires and wire connectors must be enclosed under the motor cover NOTE Lightly snug the knurled knob and make sure the wires and wire connectors are completely inside the motor coupling cover and not pinched between the motor coupling cover and the motor 15 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the top Figure 9A ...

Страница 7: ...ecessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 2 Figure 12A TOP OF HOUSING CANDELABRA BASE LAMP SOCKET Figure 10A 19 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to...

Страница 8: ...the hole in the ceiling cover is clear of the downrod 29 Attach one blade assembly to the motor hub using two 10 32 x 5 8 oval head screws supplied Figure 17A Do not tighten completely at this time Install remaining blade assemblies in the same way Gently snug all flange screws to the motor hub working around the hub in a clockwise sequence Next securely tighten all flange screws again working in ...

Страница 9: ...rs in the raised center portion of the plate assembly Do not pinch wires between the light kit plate assembly and the adapter assembly 33 Secure the light kit plate assembly to the light kit adapter assembly by threading three 5 32 32 x 3 16 phillips head screws supplied into the threaded holes in the adapter assembly Figure 20A 9 LIGHT KIT ADAPTER ASSEMBLY JUMPER ASSEMBLY SETSCREW COLLAR Figure 1...

Страница 10: ...e 5 Separate untwist and unkink the three black white and blue motor wires then route the wires through the downrod 6 Using wiring connectors supplied connect the yellow uplight lead to the yellow wire from the downrod Figure 3B Fold the yellow wire into the slot in the motor coupling slide the downrod down the wires and seat the downrod in the motor coupling 7 Align the clevis pin holes in the do...

Страница 11: ...HOUSING CANDELABRA BASE LAMP SOCKET Figure 6B DOWNROD PIN HANGER BALL CEILING COVER Figure 5B IMPORTANT A If you have installed an 18 or longer downrod and are planning to install the decorative support rods assembly proceed to INSTALLATION OF DECORATIVE SUPPORT RODS ASSEMBLY on page 14 After you have installed the decorative support rods assembly continue with the following installation procedure...

Страница 12: ...hreaded studs and turn until studs protrude through the holes in the ceiling cover Figure 11B 18 Secure the ceiling cover in place by installing two lockwashers and two knurled knobs supplied Figure 11B Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 19 Use three 10 32 x 3 8 pan head screws and fla...

Страница 13: ...Figure 15B Connect the white wire from the plate assembly to the white wire form the motor shaft using a wire connector supplied NOTE When installing the light kit plate assembly position the wires and wire connectors in the raised center portion of the plate assembly Do not pinch wires between the light kit plate assembly and the adapter assembly 25 Secure the light kit plate assembly to the ligh...

Страница 14: ...od support assembly and loosely engage the rod hook with one of the rings on the support assembly Figure 3 Then tighten the setscrew using the 5 64 setscrew 5 Engage the other two support rods in the same manner as above Loosen the setscrew and raise the rod support assembly until the support rods are taut and in line with the downrod Figure 4 Then securely tighten the setscrew using the 5 64 hex ...

Страница 15: ...ire connections in the switch housing wire connections in the switch housing 2 Fan sounds noisy 1 Blades not attached to fan 1 Attach blades to fan before operating 2 Support rods loose 2 Tighten the barrels of the rod assemblies 3 Screws securing fan blade flanges to motor hub 3 Check to make sure the screws which attach are loose the fan flanges to the motor hub are tight WARNING Make sure main ...

Страница 16: ...er Motor 761621 3 761621 17 761621 21 761621 23 761621 17 761621 21 24 Screw 8 Washerhead 4 25 Capacitor 9 mfd 762117 762117 762117 762117 762117 762117 26 Motor 762304 762304 762304 762304 762304 762304 27 Hub Motor 760601 760601 760601 760601 760601 760601 28 Flange Set Full set for one fan 762105 762105 1 762105 2 762105 3 762105 1 762105 2 29 Adapter Assembly Light Kit 762094 762094 762094 762...

Отзывы: