Mechanical Stroke Adjustment
Section 5: Mechanical Stroke Adjustment
This section explains:
•
What mechanical stroke adjustment is.
•
What the factory settings are.
•
How to adjust the travel stops.
Bettis Q-Series actuator sizes 40 to 1600 have two stroke adjustment stops for adjusting
accurately the stroke of the actuator/valve assembly in open and closed position.
The factory setting of the stroke is 90°. Most quarter-turn valve applications will not require
readjustment of these settings.
If required the stroke can be adjusted by means of two-stroke adjustment bolts.
Figure 18
Factory Setting
Limit Stop 2
Limit Stop 1
Closed
-3°
10°
Open
80°
93°
Size 950 - 1600
Size 40 - 600
90°
Closed
-5°
10°
Open
80°
95°
90°
Installation, Operation and Maintenance Manual
DOC.IOM.BQ.E Rev. 3
April 2019
25