Installation
5.
Install the actuator to the bracket. Tighten all bolts and apply the correct torque
(Refer to Table 9).
Table 9.
Bottom Flange Torque Values
Actuator Size
ISO Pattern
Torque (Nm)
Torque (lbf.ft)
Thread
Min.
Max.
Thread
Min.
Max.
40, 65, 100
F05 inner pattern
M6
4.5
5.0
1/4"-20
3.3
3.7
F07 outer pattern
M8
10.5
12.5
5/16"-18
7.7
9.2
150, 200, 350
F07 inner pattern
M8
10.5
12.5
5/16"-18
7.7
9.2
F10 outer pattern
M10
21.0
24.5
3/8"-16
15.5
18.1
600
F10 inner pattern
M10
21.0
24.5
3/8"-16
15.5
18.1
F12 outer pattern
M12
34.5
43.0
1/2"-13
25.4
31.7
950
F10 inner pattern
M10
21.0
24.5
3/8"-16
15.5
18.1
F14 outer pattern
M16
90.0
104.0
5/8"-11
66.4
76.7
1600
F16 inner pattern
M20
170.0
204.0
3/4"-10
125.4
150.5
F25* outer pattern 4x M16
90.0
104.0
4x 5/8"-11
66.4
76.7
6.
When required, mount or adjust the visual indicator (26).
Figure 17
Indicator Mounting
Indicator Mounting “In-line”
Size 40 - 600
Size 950- 1600
90°
90°
Indicator Mounting “Across Line”
Installation, Operation and Maintenance Manual
DOC.IOM.BQ.E Rev. 3
April 2019
23
Section 4: Installation