Installation, Operation and Maintenance Manual
VA-DC-000-1803 Rev. 2
July 2020
33
Section 4: Field Conversions
Field Conversions
Section 4: Field Conversions
4.1
Construction Reversal
(Exchange Module Locations)
4.1.1
Remove pneumatic power module per Section 5.1.
4.1.2
Remove M18 Hydraulic Override Cylinder per Section 5.3.
4.1.3
Using Section 5.1, reinstall the pneumatic power module onto the opposite end of
housing (1 - 10) as it was previously located.
4.1.4
Using Section 5.3, reinstall the M18 Hydraulic Override Cylinder onto the opposite
end of housing (1 - 10), as it was previously located.
4.1.5
Swap position of reservoir and manifold per section.
4.1.6
Retube as required.