background image

READ AND SAVE THESE INSTRUCTIONS

Model No.

CF2400AB00
CF2400BC00
CF2400BZH00
CF2400ORB00
CF2400PW00
CF2400SCK00
CF2400WB00

ATHENIAN

Part No. F40BP72780000

Form No. BP7278

U.L. Model No.: CF2400

Net Weight:  

21.6 

Lbs.

Ceiling Fan

Owner's Manual

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of
the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price
of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR
REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson

Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort
Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages
as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if
this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Содержание ATHENIAN CF2400AB00

Страница 1: ...eturn the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What...

Страница 2: ...ed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be moun...

Страница 3: ...urled knobs 6 Four lockwashers 7 Four wire connectors 8 Two pull chain pendants 3 9 Two couplings 10 One hairpin clip 11 One clevis pin 12 Eleven 10 32 x 5 8 oval head screws 13 Sixteen 10 32 x 3 8 Phillips pan head screws 14 Sixteen 10 flat washers 15 Three 8 32 x 3 8 pan head screws NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are ...

Страница 4: ...d to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid possible ...

Страница 5: ...he downrod Be sure the cover is oriented correctly with the large opening at the top Figure 4 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed as shown in Figure 2 could result in the fan falling WARNING LOCKWASHER 2 KNURLED KNOB 2 MOTOR COUPLING MOTOR COVER 1 THREAD...

Страница 6: ...nd seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 9 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 8 The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING To reduce the risk of personal injury...

Страница 7: ...ll switch to control your ceiling fan uplight and optional Emerson Light Fixture if installed simultaneously you will need a standard two wire with ground conductor cable between the ceiling and wall outlet boxes The fan speed and uplight can then be operated from the pull chain switches in the switch housing the optional light fixture can be operated from the light fixture switch Refer to Figure ...

Страница 8: ...ossible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING CEILING COVER THREADED STUDS 2 KNURLED KNOB 2 LOCKWASHER 2 Figure 12 SWITCH HOUSING COVER COVER PLATE FINIAL NUT Figure 13 8 32 x 3 8 PAN HEAD SCREWS 3 SWITCH HOUSING COVER Figure 15 9 Position the switch housing cover so that the tab on t...

Страница 9: ...or this fan could result in fire shock and personal injury WARNING WARNING 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the 4 position speed control switch pull chain The operating sequence is as follows THREE SPEED 1st Pull HIGH 3rd Pull Low 2nd Pull Medium 4th Pull OFF 3 If airflow is desired...

Страница 10: ...housing 5 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is not tightened 1 Raise coupling cover and tighten setscrew securely excessively securely 2 Setscrew in the hanger ball downrod assembly 2 Tighten the setscrew in the hanger ball downrod assembly is loose 3 Screws securing fan blade flanges to 3 Check to be sure screws which...

Страница 11: ...Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 ...

Страница 12: ...3 761621 23 761621 27 761621 25 761621 21 761621 24 761621 17 22 Capacitor Aux 10 uF 762242 762242 762242 762242 762242 762242 762242 23 Motor 762508 762508 762508 762508 762508 762508 762508 24 Hub Motor 760601 760601 760601 760601 760601 760601 760601 25 Flange Set Blade full set for one fan 762540 5 762540 4 762540 13 762540 12 762540 8 762540 11 762540 1 26 Housing Assembly Switch 762542 76254...

Отзывы: