Installation and commissioning
[21]
Sensor connection
The following sensor types can be connected.
•
EZ 105x and EZ 108x
•
Bently Nevada 3300 XL 8 mm Proximity Probes 33010x.
The sensor adapter EZ1900-003-ADAP-2 is required for the connection of 33010x
probes.
Figure 5-5: Sensor adapter EZ 1900-003-ADAP-2
A.
Connector to EZ 1000
B.
Label
C.
Connector to BN 33010x
D.
Total adapter length: approximately 365 mm
The sensor socket of the EZ 1000 is a mini LEMO socked with an external thread to secure
the sensor against unintentional removing.
Connect
1.
Plug the sensor connector into the sensor socket. See
for the location of
the sensor socket.
2.
Gently turn the cap nut of the sensor connector clockwise to secure the sensor.
Disconnect
1.
Turn the cap nut of the sensor connector counter clockwise to unfasten the sensor.
2.
Unplug the sensor.
Isolate the adapter connection
If using the EZ1900-003-ADAP-2 adapter to connect third party sensors to the EZ 1000
converter, isolate the connection between the sensor cable and the adapter with the
included black shrink sleeve. For installation in a hazardous environmental, also use the
included blue shrink sleeve.
Procedure
1.
At the open connection, push the shrink sleeve over the connector of the sensor
cable so that the sleeve completely covers the sensor cable.