background image

4

Model No.: ACF552

How to Put This Ceiling Fan Together

1.

Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod  (Figure  1).  Remove  the  pin  from  the
downrod,  then  remove  the  hanger  ball.  Retain  the
pin and hanger ball for reinstallation in Step 6.

2.

Separate,  untwist  and  unkink  the  four  2  m.  (80”)
motor  leads/connector.  Route  the  motor  lead
wires/connector through the downrod. 

3.

Remove  the  setscrew  from  the  motor  coupling.
Insert  the  downrod  into  the  motor  coupling.  Align
the clevis pin holes in the downrod with the holes in
the motor coupling. Install the clevis pin and secure
with the hairpin clip (Figure 2). The clevis pin must
go through the holes in the motor coupling and the
holes in the downrod. Be sure to push the straight
leg of the hairpin clip through the hole near the end
of  the  clevis  pin  until  the  curved  portion  of  the
hairpin clip snaps around the clevis pin. The hairpin
clip must be properly installed to prevent the clevis
pin  from  working  loose.  Pull  on  the  downrod  to
make sure the clevis pin is properly installed.

4.

Reinstall  the  setscrews  in  the  motor  coupling  and
tighten  securely  while  pulling  up  on  the  downrod.
(Figure 2).

NOTE:  The  setscrews  must  be  properly  installed
as described above, or fan wobble could result.

PIN

HANGER

BALL

SETSCREW

DOWNROD

Figure 1

SETSCREW

CLEVIS

PIN

DOWNROD

HAIRPIN

CLIP

MOTOR COUPLING

SETSCREW

CLEVIS PIN

HAIR PIN 

CLIP

CLEVIS

PIN

STRAIGHT 

LEG OF 

CLEVIS PIN

MOTOR COUPLING

Figure 2

DOWNROD

COUPLING 

COVER

GROMMET

CEILING COVER

Figure 3

It is critical that the clevis pin in the motor coupling

is  properly  installed  and  the  setscrews  securely

tightened. Failure to verify that the pin and setscrews

are properly installed could result in the fan falling.

WARNING

!

5.

Make sure the grommet is properly installed in the
coupling cover, then slide the coupling cover on the
downrod  until  it  rests  on  the  motor  housing.  Place
the  ceiling  cover  over  the  downrod.  Be  sure  that
the  ceiling  cover  and  the  coupling  cover  are  both
oriented correctly (Figure 3).

6.

Reinstall the hanger ball (Figure 4) on the downrod
as  follows.  Route  the  motor  leads/connector
through  the  hanger  ball.  Position  the  pin  through
the two holes in the downrod and align the hanger
ball so the pin is captured in the groove in the top
of  the  hanger  ball.  Pull  the  hanger  ball  up  tight
against the pin and securely tighten the setscrew in
the hanger ball. A loose setscrew could create fan
wobble.

It is critical that the pin in the hanger ball is properly

installed  and  the  setscrew  securely  tightened.

Failure  to  verify  that  the  pin  and  setscrew  are

properly installed could result in the fan falling.

WARNING

!

HANGER 

BALL

SETSCREW

PIN

DOWNROD

CEILING

COVER

Figure 4

Содержание ACF552ORB00

Страница 1: ...LECTRICIAN The warranty on this fan will be void if the appliance is not installed by a licensed electrician This ceiling fan is imported by MyFan as an agent for the USA design owners and can provide after sales service for this product if required Contact can be made by phone fax or email during normal trading hours Copies of owner s manuals for each model can be found on our web site Phone 1300...

Страница 2: ...nished with the fan provides the minimum recommended floor to fan blade clearance for a 2 4 m ceiling 5 The fan must be mounted with the fan blades at least 2 1 meters from the floor to prevent accidental contact with the fan blades 6 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless ...

Страница 3: ... stripper The fan must be installed by a licensed electrician WARNING THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS PORCHES PATIOS AND DECKS USE ONLY WITH LIGHT KITS MARKED SUITABLE FOR USE IN WET LOCATIONS Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been com...

Страница 4: ...ve or fan wobble could result PIN HANGER BALL SETSCREW DOWNROD Figure 1 SETSCREW CLEVIS PIN DOWNROD HAIRPIN CLIP MOTOR COUPLING SETSCREW CLEVIS PIN HAIR PIN CLIP CLEVIS PIN STRAIGHT LEG OF CLEVIS PIN MOTOR COUPLING Figure 2 DOWNROD COUPLING COVER GROMMET CEILING COVER Figure 3 It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failur...

Страница 5: ...n the third hole in the cover with vacant threaded hole on the lower housing adapter Re install the screw removed in Step 13 into the aligned holes Securely tighten all three screws figure 8 NOTE Make sure wires are not pinched between switch cup cover and lower housing adapter BLADE ASSEMBLY M6 x 14mm CAPTIVE SCREW WITH LOCKWASER REMOVE ONE M4 x 10mm SERRATED PAN HEAD SCREW LOWER HOUSING ADAPTER ...

Страница 6: ... fuse box at this time and remove the existing light fixture The hanger bracket must be securely anchored and capable of withstanding a load of at least 40kg Figure 11 depicts typical structural configuration that may be used for securely mounting the fan Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wirin...

Страница 7: ...ast 2 1 meters of clearance from floor to blades Figure 12 WARNING The hanger bracket must be securely mounted to the ceiling joist and capable of supporting at least 40 Kg WARNING How To Hang This Ceiling Fan MAIN FUSE BOX Figure 15 NOTE CEILING COVER AND FAN WIRES OMITTED FOR CLARITY 1 Turn off the branch circuit electricity at the main fuse box Figure 15 2 Plug the hanger ball green yellow grou...

Страница 8: ...e ceiling cover 3 Secure the ceiling cover in place by sliding the 8 lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 17 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling Your fan is now wired to be turned on and off from the wall switch 7 Securely connect the branch circuit supply cable green yellow earth wire to the...

Страница 9: ... 5 Screws holding blades to blade flanges 5 Tighten screws securely are loose 3 Fan wobbles 1 Setscrews in motor coupling are loose 1 Tighten both setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball assembly is loose downrod assembly 3 Screws securing fan blade flanges to 3 Check to be sure screws which attach the fan mot...

Страница 10: ...w ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING ...

Страница 11: ...ttached to the top housing For repair parts Model No ACF552 Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 2 1 m above the floor and 50 cm from the w...

Страница 12: ...btain any after sales service Keep your tax invoice or other proof of purchase together with the installing electrician s details Do not uninstall or attempt to return the product to the supplier or MyFan unless advised to by MyFan You must be the original purchaser of the product and it must be installed in its original point of installation to be covered by this warranty Warranty periods begin f...

Отзывы: