Equipment
A group of coupled devices that logically should be monitored
together. Most often a machine train is made up of a driver
component (such as a motor) and one or more driven components
(such as a pump or fan).
Component
A specific, single asset to be monitored. Motors, engines, turbines,
pumps, and fans are examples of components.
Measurement
Point
Corresponds to a single physical sensor. A Measurement Point
groups together all the data from all the collections that have been
defined for a particular sensor. Any Gross Scan data collected on the
sensor and reported for storage is logically associated with the
Measurement Point in the database.
Data Collection
Set (DCS)
The DCS is a single collection of data on a single Measurement Point.
Multiple DCSs allow multiple collections on a single Measurement
Point. The DCS combines a particular predicate (when to collect),
with a particular AP Set (what and how to collect, including
parameter bands), and a specific AL Set (alarm set points).
9.1.3
Physical hierarchy
Machinery Monitor (unit)
The physical monitoring unit.
Signal Channels
An AC vibration or DC process input.
Tachometer Channels
A speed measurement input.
Digital I/O Channels
A discrete relay, Input or Output.
9.2
View or edit IP addresses with the unit
Verify the network addresses of the computer, the unit, and the database.
Procedure
1.
Start a terminal session on the AMS Machinery Health Monitor.
If you use a serial connection with PuTTy or HyperTerminal, you do not need a
username and password.
If you use a Telnet connection, log in with the following credentials. Both are case-
sensitive:
•
username:
csi
•
password:
csiSupport
2.
At the prompt, type
bootChange
and press
Enter
. This command is case-sensitive.
A list of boot parameters appears one line at a time.
3.
Press
Enter
to advance down the list of parameters.
4.
Note the IP addresses in the following fields:
Data collection and analysis
MHM-97125-PBF-EN, R0
77
Содержание A6510
Страница 8: ...Introduction 4 MHM 97125 PBF EN R0 ...
Страница 16: ...Product Introduction 12 MHM 97125 PBF EN R0 ...
Страница 18: ...Sensor installation 14 MHM 97125 PBF EN R0 ...
Страница 28: ...Enclosure mounting 24 MHM 97125 PBF EN R0 ...
Страница 55: ...Default schema for network addressing Figure 6 11 Wire terminations MHM 97125 PBF EN R0 51 ...
Страница 56: ...Wire terminations 52 MHM 97125 PBF EN R0 ...
Страница 78: ...Software configuration 74 MHM 97125 PBF EN R0 ...
Страница 94: ...Data collection and analysis 90 MHM 97125 PBF EN R0 ...
Страница 104: ...System calibration 100 MHM 97125 PBF EN R0 ...
Страница 110: ...Data types 106 MHM 97125 PBF EN R0 ...
Страница 113: ...Index MHM 97125 PBF EN R0 109 ...