background image

4

INSTALLER/CONFIGURATION MENU 

With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will 
show item #1 in the table below. Press Menu to advance to the next menu item. Press 

 or 

 to change an item option. 

Shaded items are not available on 1F86.

1) 

Select Reversing Valve Output 

(SS/HP switch must be set 

at HP, omitted if SS/HP switch is SS Position) – The O/B 
option is factory set at "O" position. This will accommodate 
the majority of heat pump applications, which require the 
changeover relay to be energized in COOL. If the thermo-
stat you are replacing or the heat pump being installed 
with this thermostat requires a "B" terminal, to energize the 
changeover relay in HEAT, the O/B option should be set at 
"B" position.

2) 

Program Options 

1F80 only – This control can be confi gured 

for 5/2 day or 5/1/1 day programming or non-programming 
mode. The default setting is P2, indicating 5/2 day program-
ming. The programs per week can be toggled to P3 or P0 
by pressing the 

 or 

 keys. A selection of 0 Days for 

non-programmable will eliminate the need for EMR, and 
that step in the menu will be skipped.

3) 

Select Cool Savings™ and value

 – Selects the Cool 

Savings feature On or OFF. If selected On, press MENU 
to select the amount of adjustment for the feature in Cool 
mode with 1 (1°) being the least amount of adjustment and 
6 (6°) being the most amount of adjustment. Default value 
is 3 (3°). In normal operation 

"Saving"

 will appear under 

"Fan"

.

 

Cool Savings is an optional energy saving feature that can 
reduce your cooling costs. It is based on the principal that 
lower indoor humidity makes a slightly higher temperature 
feel more comfortable. Cool Savings operates during periods 
of high demand which normally occur on the hottest summer 
days when the cooling system may run for hours to reach 
the thermostat setting. Long cooling run times also lower the 
indoor humidity. Cool Savings very slowly adjusts the setpoint 
temperature to make the setpoint closer to the displayed 
temperature, to a maximum number of degrees selected. 
Adjusting the setpoint temperature over a long cooling run 
time allows the system to reach your set temperature and 
turn off. The room temperature will actually be higher than 
the thermostat displays, but the reduction in humidity will 
allow comfort at the slightly higher temperature. When Cool 
Savings is making adjustments, "Save" will show next to the 
setpoint temperature and the room temperature may vary 
within the adjustment range selected. 

 

If this feature is selected OFF, no change will occur when 
the cooling system is continually running during periods of 
high demand.

INSTALLER/CONFIGURATION MENU

MENU

REF

HP

SS

PRESS 

BUTTON

DISPLAYED

(FACTORY DEFAULT)

Press 

 or 

 to 

select from listed options

COMMENTS

1

1

MENU

On (Cool O)

Heat b On

Reversing Valve Output (SS/HP switch 

must be in the Heat Pump HP position)

2

2

1

MENU

P (2)

P 3, P 0

Selectable Programs Per Week 

(For programmable thermostat only)

3

3

2

MENU Cool Saving CS (OFF)

Cool Saving CS On

Select Cool Savings on or off

MENU

CS (3)

6, 5, 4, 2, 1

Selects Cool Savings value 1 (low) to 6 (high)

4

4

3

MENU

E (On)

E OFF

Selects Energy Management Recovery (EMR) 

on or off

5

4

MENU

CR Heat

(ME)

FA, SL 

Adjustable Anticipation (Heat) (only when 

SS/HP switch is at the SS position)

6

5

MENU

CR Cool

(FA)

SL

Adjustable Anticipation (Cool) (only when 

SS/HP switch is at the SS position)

7

5

MENU

CR Heat Pump

(FA)

SL

Adjustable Anticipation (Heat Pump) 

(only when SS/HP switch is at the HP position)

8

6

6

MENU

CL (OFF)

CL On

Compressor Lockout Time

9

7

7

MENU

Auto Heat

Cool Off

Heat Cool Off,

Heat Off with Fan icon,

Heat Off without Fan

icon, Cool Off,

Auto Off

System Mode Confi guration 

with Automatic Changeover

10

8

8

MENU

L (On)

L OFF

Selects Display Light on or off

11

9

9

MENU

0 HI

1 HI, 2 HI, 3HI, 4 HI,

1 LO, 2 LO, 3 LO, 4 LO

Adjustable Ambient Temperature Display

12

10

10

MENU

F

C

Selects Fahrenheit/Celsius Temperature Display

13

11

11

MENU

Change Filter (OFF)

Change Filter On

Selects Filter Change-out Indicator

MENU Change Filter 200 h

25 h to 1975 h in

25-hour increment

When on, selects time in 25 hour increments 
 

 

 

 25-hour increment

14

12

12

RUN

Returns to Normal Operation

Содержание 1F80-0471

Страница 1: ...ntial Single Stage Heat 0 6 F Cool 1 2 F adjustable Differential Heat Pump Heat 1 2 F Cool 1 2 F adjustable Operating Ambient 32 to 105 F 0 to 41 C Operating Humidity 90 non condensing max Shipping Temperature Range 4 to 150 F 20 to 65 C Dimensions Thermostat 3 4 H x 4 4 W x 1 3 D Topreventelectricalshockand orequipmentdamage disconnect electric power to system at main fuse or circuit breaker box ...

Страница 2: ...ing a call for heat If your heat is gas or oil the switch should be set to the GAS position When the thermostat is configured for Heat Pump the thermo stat will always power the circulator fan on a call for heat in the HEAT mode 2 Batteries 2 AA alkaline batteries are included in the thermostat To in stall the batteries pull the battery door as shown by the arrow and lift open Using the polarity i...

Страница 3: ...Mode 7 Displays Run Schedule Schedule or Menu 8 Displays Save when Cool SavingsTM is working 9 Displays Heat Pump when system is configured as Heat Pump thermostat 10 Displays Hold in programmable mode when in Hold mode Displays Light Bulb in non program mable mode 1 Flame icon is displayed when the system is in HEAT mode Snowflake icon is displayed when the system is in COOL mode 2 The word Hold ...

Страница 4: ...he displayed temperature to a maximum number of degrees selected Adjusting the setpoint temperature over a long cooling run time allows the system to reach your set temperature and turn off The room temperature will actually be higher than the thermostat displays but the reduction in humidity will allow comfort at the slightly higher temperature When Cool Savings is making adjustments Save will sh...

Страница 5: ...ash the setpoint for up to five minutes 9 System Mode Configuration This thermostat is configured for Heat and Cool withAuto changeover SYSTEM switch with Cool Off Heat Auto default It can also be configured for Heat and Cool Cool Off Heat Heat only with fan Off Heat Heat only without fan Auto only Auto Off and Cool only Cool Off 10 Select Backlight Display The display backlight improves display c...

Страница 6: ...d then press Schedule 3 The top of the display will show the day s being pro grammed The time and temperature flashing are also displayed 1 will also be displayed to indicate the period 4 Press or button to change the temperature to your selected temperature for the 1st heating period 5 Press Time button time will flash 6 Press or button to adjust the start time for the 1st period 7 The time will ...

Страница 7: ...ing guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save energy If you plan on using Auto Changeover do not program the heating higher than the cooling Worksheet for Re Programming 5 2 Day and 5 1 1 Day Program PROGRAMMING For Programmable Model Only Wake Up Period 1 Leave For Work Period 2 Return Home Period 3 Go To ...

Страница 8: ...k Try resetting the thermostat as described above If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system oper ates correctly replace the thermostat Thermostat Setting Thermostat Thermometer Disagree 1 Thermostat thermometer setting requires adjustment The thermometer can be adjusted 4 degr...

Страница 9: ... 6 F frío 1 2 F ajustable Diferencial bomba de calor Calor 1 2 F frío 1 2 F ajustable Temperatura ambiente operativa 32 F a 105 F 0 C a 41 C Humedad operativa 90 sin condensación máx Rango de temperatura de transporte 4 F a 150 F 20 C a 65 C Dimensiones del termostato 3 4 pulg Al x 4 4 pulg An x 1 3 pulg P Paraevitardescargaseléctricasy odañosalequipo desconecte la alimentación eléctrica en la caj...

Страница 10: ...rruptor debe ajustarse en la posición GAS Cuando está configurado para bomba de calor el termostato siempre activa el ventilador circulador en una llamada de calor en el modo HEAT pilas alcalinas AA Figura 1 Puerta del compartimiento de las pilas abierta Orificio de montaje Orificio de montaje Colocar nivelado a través de las lengüetas de montaje sólo por razones estéticas SS HP GAS ELEC Interrupt...

Страница 11: ...ule programa o Menu menú 8 Muestra Save ahorro cuando Cool SavingsTM está en funcionamiento 9 Muestra Heat Pump bomba de calor cuando el sistema está configurado como termostato de bomba de calor 10 Muestra Hold mantener en el modo programable cuando está en el modo Hold Muestra Light Bulb bombilla en el modo no programable 1 El icono de la llama aparece cuando el sistema está en el modo HEAT El i...

Страница 12: ...viene ajustada de fábrica en la posición O Esta posición admite la mayoría de las aplicaciones de bomba de calor que requieren que el relé de conmutación esté energizado en COOL Si el termostato que está cambiando o la bomba de calor en la que está instalando este termostato requiere una terminal B para energizar el relé de conmutación en HEAT el interruptor O B debe colocarse en la posición B 2 O...

Страница 13: ...r del termostato la pantalla mostrará la temperatura de referencia de forma intermitente durante un máximo de cinco minutos 9 Configuración del modo del sistema Este termostato está configurado para calor y frío con opción predeterminada de conmutación automática interruptor SYSTEM con Cool Off Heat Auto También puede configurarse para calor y frío Cool Off Heat sólo calor con ventilador Off Heat ...

Страница 14: ...AUTO el termostato cambiará a Heat o Cool según cuál fue el último que se ejecutó Si cambia a calor pero usted desea frío o si cambia a frío pero usted desea calor presione los botones o simultáneamente para pasar al otro modo Ajuste la hora y día actuales 1 Presione Menu y luego el botón Time una sola vez La pantalla mostrará la hora únicamente 2 Presione y mantenga presionado los botones o hasta...

Страница 15: ...n programa de 5 2 días ingrese sus propias horas y temperaturas directamente a continuación debajo de las horas y temperaturas de fábrica Si desea reprogramar con un programa de 5 1 1 días complete todas las líneas con las horas y temperaturas que desea Tenga en cuenta las siguientes indicaciones cuando planifique su programa En calefacción las temperaturas más bajas ahorran energía En enfriamient...

Страница 16: ...N Verifique todas las conexiones de los cables para asegurarse de que no estén en cortocircuito o tocándose entre sí No debe sobresalir ningún cable pelado por debajo del bloque de terminales Intente reajustar el termostato como se describe más arriba Si la condición persiste el fabricante de su sistema o el personal técnico podrá indicarle cómo probar si el sistema de frío calor está funcionando ...

Отзывы: