INSTALLATION---Selecting the Installation Place   

 Install the indoor unit level on a strong wall that is not 

     subject to vibrations.

 The inlet and outlet ports should not be obstructed: the

     air should be able to blow all over the room.

 Do not install the unit near a source of heat, steam, or 

     flammable gas.

 Install the unit near an electric socket or private circuit.
 Do  not  install  the  unit  where  it  will be exposed to 

     direct sunlight.

 Install the unit where connection between indoor and 

     outdoor unit is as easy as possible.

 Install the unit where it is easy to drain the condensed 

     water.

 Check the machine operation  regularly and  leave the 

     necessary space (as shown in the picture).

 Install the indoor unit where  the  filter  can  be easily 

     accessible.

condensed water drain pipe

6

or

150mm

Sleeve

insulating covering

electrical cable

Mounting plate

 Do not install the outdoor  unit  near  sources of  heat,

     steam or flammable gas.

 Do not install the unit in too windy or dusty places.
 Do not install the unit where people often pass.Select

     a place where the air discharge and  operating  sound 
     level will not disturb neighbours.

 Avoid  installing  the  unit  where it  will  be exposed 

     to direct sunlight  ( other wise  use  a  protection ,  if 
     necessary, that should not interfere with the air flow).

 Leave space as shown in the picture for the air to 

     circulate freely.

 Install the outdoor unit in a safe and solid place.
 If the outdoor unit is subject to vibration, place rubber 

     gaskets onto the feet of the unit.

water drain pipe

Minimum required installation space

Outdoor unit

Indoor unit

 Pipe length is
 

50' (15m)Max

 b

le

ss

 t

h

an

 5

m

 

H

ei

g

h

 s

h

o

u

ld

Outdoor unit

Indoor unit

Pipe length is

(15m)

50' Max

 b

le

ss

 t

h

an

 5

m

 

H

ei

g

h

 s

h

o

u

ld

 

            Installation Diagram

INDOOR UNIT

   

OUTDOOR UNIT

   

Only persons and/or companies qualified and experienced in the installation, service and repair of refrigerant  
products  should  be permitted to do so. The purchaser must ensure that the person and/or company who is to 
install, service or repair this air conditioner has qualifications and experience in refrigerant products.

20
500mm

20
500mm

12
300mm

12
300mm

79
2000mm

6

or

150mm

6

or

150mm

Содержание 19 SEER Series

Страница 1: ......

Страница 2: ......

Страница 3: ...MMENDATIONS FOR THE INSTALLER NAMES OF THE PARTS INDOOR UNIT DISPLAY OPERATING INSTRUCTIONS PROTECTION INSTALLATION MANUAL MAINTENANCE TROUBLESHOOTING EMERGENCY FUNCTION AUTO RESTART FUNCTION REMOTE CONTROL 1 4 5 6 7 11 18 20 27 28 ...

Страница 4: ...uld be disposed of in the separate waste bins Take the air conditioner at the end of its life to waste collection center for disposal an authorized Only use the air conditioner as instructed in this booklet These instructions are not inten ded to cover every possible condition and situation As with any electrical household appliance common sense and caution are therefore always recommended for ins...

Страница 5: ...r any other purpose such as for drying clothes cooling food etc The packaging materials are recyclable and should be disposed of in waste bins Take the air conditioner at the end of its life to waste collection for disposal separate an authorized center Only use the air conditioner as instructed in this booklet These instructions are not intend ed to cover every possible condition and situ ation A...

Страница 6: ...open when the air conditioner is operating Do not direct the airflow onto plants or anim als A long direct exposition to the flow of cold air of the conditioner could have negative effects on plants and animals Do not put the conditioner in contact with water The electrical insulation could be damaged and thus causing electrocution Do not climb onto or place any objects on the outdoor unit Never i...

Страница 7: ...ition optional 18 Outdoor unit rating label WALL AIR CONDITIONER The is made up of two or more units connected between themselves through copper pipes properly insulated and an electrical connecting cable air conditioner The indoor unit is installed on the walls of the room to be conditioned The outdoor unit is installed on the floor or on the wall on suitable brackets Technical data of the air co...

Страница 8: ...r Example it is on the display of the remote controller but on the indoor display 4 2 3 1 2 5 4 No Led Function POWER The symbol appears when power on 1 2 3 4 5 Temperature display if present Error code 1 Lights up during Timer operation when the air conditioner is operational 2 Displays the malfunction code when fault occurs SLEEP mode Lights up during Timer operation The symbol appears when the ...

Страница 9: ...r 5 seconds the unit will turn off For cooling only model press the emergency button at first time the unit will operate in COOL mode Press again the unit will turn off If the remote controller fails to work or maintenance necessary proceed as following EMERGENCY FUNCTION AUTO RESTART FUNCTION The appliance is preset with an auto restart function In case of a sudden power failure the module will m...

Страница 10: ...eactivate the ECO function ECO To set the automatic switch on off time TIMER To switch on off of the function SLEEP SLEEP 10 To switch on off of the LED display DISPLAY To switch on off of the auto swing function of the flaps SWING 12 To switch on off of the Mute function MUTE 13 To switch on off of the follow me function I FEEL 14 To switch on off of the health function which controls the ionizer...

Страница 11: ... indicators may vary according to the model but their function is the same The display and some functions of the remote control may vary according to the model The unit confirms the correct reception of each button with a beep REMOTE CONTROL ...

Страница 12: ...uto low mid high 13 SUPER function indicator 14 15 Mute function indicator 16 Up down auto swing indicator 17 Temperature indicator Meaning No Symbols Left right auto swing indicator SLEEP function indicator Timer indicator Battery indicator Auto Mode function indicator Health function indicator I FEEL functions indicator ECO Mode indicator The display and some functions of the remote control may ...

Страница 13: ...onditioner 2 Check that there are no objects between the remote control and the Signal receptor in the indoor unit 3 Never leave the remote control exposed to the rays of the sun 4 Keep the remote control at a distance of at least 1m from the television or other electrical appliances Note Please remove batteries to avoid leakage damage when not using for a long time Signal receptor REMOTE CONTROL ...

Страница 14: ...to activate the louver 1 Press to activate the horizontal flaps to swing from up to down Press again to stop the swing movement at the current angle 2 Press to active the vertical deflectors to swing from left to right Press again to stop the swing movement at the current angle 2 If the vertical deflectors are positioned manually which placed under the flaps they allow to move the air flow direct ...

Страница 15: ...With the button or set a temperature lower than that of the room To activate the heating function HEAT press the MODE button until the symbol appears on the display With the button or set a temperature higher than that of the room In HEATING operation the appliance can automatically activate a defrost cycle which is essential to clean the frost on the condenser so as to recover its heat exchange f...

Страница 16: ... the DRY mode Press MODE until appears in the display An automatic function of pre setting is activated FAN Fan mode air ventilation only To set the FAN mode press MODE until appears on the display AUTO MODE Automatic mode AUTO To set theAUTO mode press MODE until appears on the display In AUTO mode the run mode will be set automatically according to the room temperature ...

Страница 17: ...LED display SLEEP Pre setting automatic operating program After 10 hours running in sleep mode the air conditioner will change to the previous setting mode Press SLEEP button to activate the SLEEP function and appears on the display Press again to cancel this function FAN function FAN button FAN Change the operating fan speed Press FAN button to set the running fan speed it can be set to AUTO LOW ...

Страница 18: ...ance will run in ECO mode Press again to cancel it NOTE The ECO function is available in both COOLING and HEATING modes Turbo function TURBO To activate turbo function press the TURBO button and will appear on the display In COOL HEATmode when you select TURBO feature the appliance will operate the highest fan speed to blow the strong airflow Press again to cancel this function ...

Страница 19: ...Dry by press the MODE button And set the needed fan speed by press FAN button And press or to set the needed operation temperature 3 Press TIMER button at the second time to set the switch on Press or to set the needed timer 4 Press TIMER button at the third time to confirm CANCEL it by press TIMER button When the unit is switch on you can set the TIMER OFF To set the time of automatic switch off ...

Страница 20: ...l appear on the remote display Do it again to deactivate this function This function enables the remote control to measure the temperature at its current location and send this signal to the air conditioner to optimize the temperature around you and ensure the comfort It will automatically deactivate 2 hours later Indoor unit Outdoor unit Temp 86 30 41 5 Temp 86 30 To active this function press an...

Страница 21: ...ration the system does not restart immediately until after 3 minutes protection function for the compressor Inverter air conditioner MODE Temperature Room Temperature Outdoor Temperature Cooling operating Heating operating Drying operating 17 32 63 89 0 30 32 86 17 32 63 89 For models with low temperature cooling system 15 53 5 127 15 53 59 127 25 30 13 86 For models with low temperature heating s...

Страница 22: ...laces Do not install the unit where people often pass Select a place where the air discharge and operating sound level will not disturb neighbours Avoid installing the unit where it will be exposed to direct sunlight other wise use a protection if necessary that should not interfere with the air flow Leave space as shown in the picture for the air to circulate freely Install the outdoor unit in a ...

Страница 23: ...rical connections see the circuit diagram on the electrical cover 4 Connect the cable to the wiring terminal by following the numbering Use wire size suitable to the electric power input see name plate on the unit and accord ing to all current national safety code requirements 5 The cable connecting the outdoor and indoor units must be suitable for outdoor use 6 The plug must be accessible also af...

Страница 24: ...o create siphons 2 The drain hose must slant downwards to aid drainage 3 Do not bend the drain hose or leave it protruding or twisted and do not put the end of it in water If an extension is connected to the drain hose ensure that it is lagged when it passes into the indoor unit 4 If the piping is installed to the right the pipes power cable and drain hose must be lagged and secured onto the rear ...

Страница 25: ...should be installed on a solid wall and fastened securely The following procedure must be observed before co nnecting the pipes and connecting cables decide which is the best position on the wall and leave enough space to be able to carry out maintenance easily Fasten the support to the wall using screw anchors which are particularly suited to the type of wall Use a larger quantity of screw anchor...

Страница 26: ...h excessive tightening torque there will also be some leakage as the flange could be damaged 3 The surest system consists in tightening the connecti on by using a fix wrench and a torque wrench in this case use the table on page 24 ELECTRICAL CONNECTIONS CONNECTING THE PIPES tap 1 Remove the handle on the right side plate of outdoor unit 2 Connect the power connection cord to the terminal board Wi...

Страница 27: ...24 BLEEDING Wrap applying correctly correctly correctly correctly INSTALLATION MANUAL Installation of the outdoor unit INSTALLATION MANUAL operation test ...

Страница 28: ... 24K Liquid pipe diameter Gas pipe diameter Lengh of pipe with standard charge Maximum distance between indoor and outdoor unit Max diff in level between indoor and outdoor unit Type of refrigerant 1 4 6 35 1 4 6 35 1 4 6 35 3 8 9 52 3 8 9 52 3 8 9 52 1 4 6 35 1 2 12 7 7 5m 25ft 15m 49ft 20g m 5m 16ft North American INVERTER TYPE Additional refrigerant charge R410A R410A R410A R410A 36K 5 8 15 88 ...

Страница 29: ...t the wiring diagram is l on the backside of the outdoor handle cover affixed to the ocated ocated Front panel Wiring diagram Wiring diagram Outdoor handle cover INSTALLATION MANUAL Information for the installer CABLE WIRES SPECIFICATION 18K 24K Power supply cable Connection supply cable 3 L 2 N 1 S N L2 L L1 sectional area AWG North American INVERTER TYPE MODEL capacity Btu h 9K 115V 12K 115V AWG...

Страница 30: ...the hinges to make the cleaning easier 2 Clean the indoor unit using a cloth with water not higher than 104 40 and neutral soap Never use aggressive solvents or detergents 3 remove by lifting up and If the battery of the outdoor unit is clogged remove any leaves or waste by hand and remove the dust with an air jet or a bit of water END OF SEASON MAINTENANCE 1 Disconnect the automatic switch or the...

Страница 31: ...ure and does not indicate a problem Unsuitable temperature setting Obstructed air conditioner intakes and outlets Dirty air filter Fan speed set at minimum Other sources of heat in the room No refrigerant Remote control is not close enough to indoor unit The batteries of remote control need to be replaced Obstacles between remote control and signal receiver in indoor unit Active LIGHT function Pow...

Страница 32: ...For any questions or Technical Support Please Call Customer Service 1 844 801 8880 ...

Отзывы: