Specifications 

Elevator Wiring 
Requirements: 

One pair of communication cable, minimum 24AWG, ideally 
shielded with the shield grounded at the controller end of the 
traveling cable. 

Power 

12-24V DC 100 mA (preferably with battery backup) 

LED 

Operating voltage 1.7 – 2.1 V 
Operating current 10 – 25 mA 

Operating Range 

0 – 60°C 

Dimensions 

PCB 1.5” (38 mm) wide x 2.25” (57 mm) high and 
0.5” (13 mm) deep with 
mounting holes 1.1” (28 mm) wide x 1.85” (47 mm) high. 
LED hole ¼” 

 

Warranty 

SHIPPING AND LIABILITY 

Please verify that the shipment is received in good order ASAP. 

EmerCom Technologies Inc. warrants parts and labor on all equipment of its own manufacture 
for a period of 10 years from the date of shipment but cannot be held liable for any loss or 
damage resulting from causes beyond their reasonable control. Any abuse, vandalism, 
alteration or misuse of these products for purposes or in a manner other than that for which they 
were manufactured will void the warranty. 

Please return defective products prepaid to your nearest service center after first calling 
1-604-589-3899 (or toll-free 1-844-363-7266) for a Return Authorization (RMA) number. Please 
provide: 

  Model number 

  Problem or fault description 

  Name of the person requesting the RMA, phone number and shipping address 

Please reference the RMA number clearly on all packaging and paperwork. 

Note:  Statistically, more field problems are caused by wiring, connection, power supply or 
installation issues rather than the devices themselves.  Please have your field staff call us from 
site before concluding that an EmerCom product needs to be returned, to offer you the 
assistance to resolve the problem most conveniently over the phone. 

EmerCom Technologies Inc. shall not be liable for any loss or damage resulting from causes 
beyond its reasonable control and in no event whatsoever shall we be liable for consequential 
damages resulting in personal injuries, property damage or economic loss to any party. 

 

Rev: 3p0a 

Содержание EMC-ALRM

Страница 1: ...EMC ALRM USER GUIDE Phone Line Monitoring System EMC 60 Hands Free Phone EMC ALRM Board...

Страница 2: ...lect the test time in seconds and touch For High Rise test Disconnect phone line to the CAB at the EMCS Try calling the cab for quick test to verify alarm Reconnect to reset then repeat but wait for a...

Страница 3: ...s the operability of the telephone line and signals the EMC ALRM if the line is not functional In the event of a phone line failure the EMC ALRM activates an audible and illuminated visual signal for...

Страница 4: ...line 12 24 V DC power EmerCom EMC 60 Hands Free Elevator Phone EmerCom EMC ALRM Board from other EMC 60 phones in the group for Low Rise w o EMCS An EMC PAC Battery backed up Power Supply and Connecto...

Страница 5: ...uide 5 EMC PAC and EMC ALRM Low Rise Layout Group B Group A Telco Phone Line EMC PAC 110 V AC EMC 60 Hands free phones in elevator cabs EMC ALRM EMC ALRM Shielded Twisted Pair STP battery 110V Supply...

Страница 6: ...de 6 EMCS and EMC ALRM High Rise Layout Group B Group A Phone lines EMCS 110 V AC EMC 60 Hands free phones in elevator cabs Security Desk EMC ALRM EC MR s Shielded Twisted Pair STP Shielded CAT 5 110V...

Страница 7: ...eature is available in the EMC 60 phone to simulate an alarm by opening the relay contacts for the number of seconds entered Command 24 after which it returns to normal An extended test can be conduct...

Страница 8: ...or in a manner other than that for which they were manufactured will void the warranty Please return defective products prepaid to your nearest service center after first calling 1 604 589 3899 or to...

Отзывы: