background image

EMC-ALRM User Guide 

 

 

 

- 3 - 

Contents 

About the EMC-ALRM Phone Line Monitoring Alarm Board ........................................................................ 3 
EMC-60 and EMC-ALRM Connections ........................................................................................................... 4 
EMC-PAC and EMC-ALRM Low-Rise Layout .................................................................................................. 5 
EMCS and EMC-ALRM High-Rise Layout ....................................................................................................... 6 
Description of Operation .............................................................................................................................. 7 
Troubleshooting ............................................................................................................................................ 7 
Specifications ................................................................................................................................................ 8 
Warranty ....................................................................................................................................................... 8 
 

About the EMC-ALRM Phone Line Monitoring 
Alarm Board 

Key Features: 

  Complies with ANSI A17.1/CSA B44 Safety Code for Elevators 

  The EMC-60 Emergency Hands-free Elevator Phone, combined with the EMCS 

Emergency Phone Consolidator, if applicable, verifies the operability of the 
telephone line and signals the EMC-ALRM if the line is not functional. 

  In the event of a phone line failure, the EMC-ALRM activates an audible and 

illuminated visual signal for each group of elevators. 

  The key-switch or pushbutton, accessible only to authorized personnel, will 

silence the audible signal for no less than 12 hours. 

  The EMC-60/EMCS monitors the failed phone line repeatedly and will signal the 

EMC-ALRM to cancel the alarm immediately. 

  The illuminated visual signal will extinguish and the system return to normal.  

Battery backed-up power is recommended to enable notification of elevator 
communications failure in the event of power failure (built-in when using an EMCS or 
EMC-PAC). 

Содержание EMC-ALRM

Страница 1: ...EMC ALRM USER GUIDE Phone Line Monitoring System EMC 60 Hands Free Phone EMC ALRM Board...

Страница 2: ...lect the test time in seconds and touch For High Rise test Disconnect phone line to the CAB at the EMCS Try calling the cab for quick test to verify alarm Reconnect to reset then repeat but wait for a...

Страница 3: ...s the operability of the telephone line and signals the EMC ALRM if the line is not functional In the event of a phone line failure the EMC ALRM activates an audible and illuminated visual signal for...

Страница 4: ...line 12 24 V DC power EmerCom EMC 60 Hands Free Elevator Phone EmerCom EMC ALRM Board from other EMC 60 phones in the group for Low Rise w o EMCS An EMC PAC Battery backed up Power Supply and Connecto...

Страница 5: ...uide 5 EMC PAC and EMC ALRM Low Rise Layout Group B Group A Telco Phone Line EMC PAC 110 V AC EMC 60 Hands free phones in elevator cabs EMC ALRM EMC ALRM Shielded Twisted Pair STP battery 110V Supply...

Страница 6: ...de 6 EMCS and EMC ALRM High Rise Layout Group B Group A Phone lines EMCS 110 V AC EMC 60 Hands free phones in elevator cabs Security Desk EMC ALRM EC MR s Shielded Twisted Pair STP Shielded CAT 5 110V...

Страница 7: ...eature is available in the EMC 60 phone to simulate an alarm by opening the relay contacts for the number of seconds entered Command 24 after which it returns to normal An extended test can be conduct...

Страница 8: ...or in a manner other than that for which they were manufactured will void the warranty Please return defective products prepaid to your nearest service center after first calling 1 604 589 3899 or to...

Отзывы: