EMC-PAC User Guide
- 2 -
Quick start guide
Customer Care: Call 1-844-EMERCOM (1-844-363-7266) for assistance.
Connect alarm board
GROUP A to PLM IN
PWR –OUT+ to +12-12VDC-
Connect 2nd alarm board (if required)
GROUP B to PLM IN
PWR –OUT+ to +12-12VDC-
Connect power
16.5VAC to PWR IN
12V (from battery) to +BAT
2
3
4
Connect first station phone line alarm
STN#1 to PLM on EMC-60 phone
Connect additional stations (as required)
STN#X to PLM on EMC-60 phon
1
Troubleshoot alarms (if any)
POWER ON for normal operation
Change battery if REPLACE BATTERY alarm
No input power detected if NO MAINS alarm
Refer to troubleshooting in manual if FAULT
alarm
5
Configure STN#1 group
Move jumper to GROUP A or GROUP B
Configure additional station’s group
Move jumper to GROUP A or GROUP B or
DISABLED