HEAT PUMP WATER HEATER 

USER MANUAL

SAFETY MEASURES

 

Do not insert any objects or obstruct the air inlets and outlets. The high speed internal rotor could cause damage or injury.
In the event of any unusual activity, such as a burning smell, turn off the manual power switch immediately and contact a 

authorised service technician.
When the unit needs to be repaired, removed or re-installed contact an authorised service technician.
Do not install the unit where there is potential for combustable gas leaks as it may cause a fire.
Confirm the installation base is strong enough to support the unit prior to install. If the base is not strong enough over  

the long term it could cause device failure or injury.
Turn the power off before cleaning the unit.

MODEL NUMBER: EE-HWS-SSHP-200 

Thank you for choosing Emerald Energy. 

This leaflet contains important information on the correct 

installation and operation of your heat pump water heater. 

PACKING LIST

1 User manual

1  Heat pump unit

1  Water tank unit

1  TPR valve

1  Condensation drainage pipe 

2  Soft connecting pipe

 WARNING  For outdoor use only.

Please read all the information before commencing  

installation and retain for future reference.

This appliance must be installed, commissioned, and serviced by 

an authorised technician in accordance with these instructions.
This unit requires reliable earthing and connection before use.
In areas vulnerable to lightening strikes lightning protection  

measures must be carried out.
This unit is not suitable for use in cold winters. Water reserved in 

the pipe system must be drained.

POWER SUPPLY:

 220V-240V/1N

~

50Hz

ENVIRONMENT TEMPERATURE:

 -7

°

C ― 43

°

C

Working water temperature: 

Min inlet water temperature 8°C, 

Max outlet Water Temperature 60°C. If the system is always used 

beyond the available range, please contact with manufacturer

Содержание EE-HWS-SSHP-200

Страница 1: ...d Energy This leaflet contains important information on the correct installation and operation of your heat pump water heater PACKING LIST 1 User manual 1 Heat pump unit 1 Water tank unit 1 TPR valve...

Страница 2: ...ments 6 Electrical work must be insulated and compliant with electrical technical standards 7 The unit must be powered for 3 4 hours before use INSTALLATION SPACE 1 Check space for maintenance before...

Страница 3: ...inlet and outlet pipe for hanging Refer to the Hoisting Heat Pump diagram PLUMBING CONNECTION Connecting water inlet and outlet pipes To house Hot water To drain Cold water Control panel Water temper...

Страница 4: ...0mm female thread 2 The hot water supply should be connected to a 20mm socket 3 To ensure thermal efficiency all hot water lines and connections must be insulated with a minimum 13mm closed cell insul...

Страница 5: ...nection Wiring must be conducted by a professional installation technician in accordance with the circuit diagram The power and signal line layout should be neat and not in contact with each other or...

Страница 6: ...Display Timer mode ECO mode Constantly bright In the range of timer period Flashing Set starting time for timer mode Constantly bright Out of the range of timer period Flashing Set ending time for ti...

Страница 7: ...inspection of controller screen System is OFF make sure the system connects with power supply less than 5 minutes before operation Press all 4 buttons simultaneously for 5 seconds to restore the fact...

Страница 8: ...y ELECTRIC HEATER CONTROL BOOSTER MODE 1 To turn on off electric heating element Press both buttons simultaneously for more than 3 seconds 2 The electric heating element will heat the water to the set...

Страница 9: ...ng element 16 0 OFF 1 ON Compressor running time before defrost 17 Real accumulated time Back up linked switch 18 0 open 1 close Programme version 19 Show real version No MANUAL STERILIZATION 1 If the...

Страница 10: ...sorb temperature sensor and outlet water temperature sensor return water temperature sensor are faulty CONTROLLER INSTRUCTIONS THE ALARM LOW PRESSURE FAULT 1 If the compressor starts running for 5 min...

Страница 11: ...red Regularly check the reliability of the electrical components Change any faulty or unreliable components After a long period of operation there will be a build up of calcium oxidized or other miner...

Страница 12: ...d inlet or compressor suction pipe is blocked expansion valve unadjusted or failed The refrigerant is not enough in the sytem Adjust suitable overheat temperature examine whether there is Fluo rine le...