3.1 Hydraulic connections, hoses
Unplug instrument from main power supply then perform connections to probes and / or selected outputs by following the
above picture. Hydraulic connections are:
Suction Hose with level probe and foot
fi
lter
Delivery Hose with injection valve
Discharge Hose
Suction Hose.
Completely unscrew tightening nut from pump’s head and remove assembling
components: tightening nut, holding ring and pipe holder.
Assembly as shown. Insert hose into pipe holder until it reaches the bottom.
Lock hose on pump’s head by screwing down the tightening nut.
Use only hands to do it!
Connect other side of the hose to the foot
fi
lter using the same procedure.
Delivery Hose.
Completely unscrew tightening nut from pump’s head and remove assembling
components: tightening nut, holding ring and pipe holder.
Assembly as shown. Insert hose into pipe holder until it reaches the bottom.
Lock hose on pump’s head by screwing down the tightening nut.
Use only hands to do it!
Connect other side of the hose to the injection valve using the same
procedure.
Discharge hose.
Insert one side of discharge hose into pump head discharge connector.
Insert other side of discharge hose into product’s tank.
During priming procedure product exceeding will
fl
ow into tank.
Suction Hose
Tightening Nut
Holding Ring
Pipe Holder
O-ring
Valve