Chapter 4: Subsystem Connection and Operation
4-7
Figure 4-3: Power Switches
CAUTION!
Although the PSUs are redundant and a single PSU can provide sufficient power to
the subsystem, it is advisable to turn both of the power switches on. If only one PSU is
operating and fails, system operation will be terminated.
4.3.4 Power On Status Check
Once the subsystem has been powered on, the status of the entire subsystem should be checked to
ensure that everything is running smoothly and that there are no complications or malfunctions.
Controller Module LEDs
– The
controller ready
LED should flash green.
Drive Tray LEDs –
The drive status LEDs (that contain hard drives) should all
lights blue.
Firmware and RAIDWatch
– The overall status of the system may be checked
using the embedded firmware utility or the RAIDWatch GUI screen.
Audible Alarm -
If any errors occur during the initialization process, the onboard
alarm will sound in a hastily repeated manner.
Drive tray LEDs should normally start flashing right after power-on, indicating the RAID
control unit is attempting to access the hard drives.
NOTE:
The subsystem has been designed to run continuously. Even if a component failure
occurs the fault can be corrected online.
Содержание SecurStor 16i
Страница 11: ...SecurStor 16i Installation and Hardware Reference Manual xi This page intentionally left blank...
Страница 12: ......
Страница 25: ...Chapter 1 Introduction 1 13 This page intentionally left blank...
Страница 26: ......
Страница 36: ......
Страница 46: ......
Страница 76: ......
Страница 91: ...Appendix C Uninterruptible Power Supply C 5 This page is intentionally left blank...