Data Domain DD4200 Storage System

FiGurE 1: rEar PanEl anD inPut/outPut connEctivity

Slot MGMT A

Slot 0

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 9

Slot 10

Management 

module

FC, Ethernet  

or empty

FC, Ethernet  

or empty

FC, Ethernet  

or empty

FC, Ethernet  

or empty

Ethernet  

or empty

Ethernet  

or empty

Empty

SAS

SAS

BBU

NVRAM

FiGurE 3: ES30 ExPanSion SHElF

Expansion shelf disk-drive numbering and components:

Note:  

Physical numbering of the disks is 0-14  

while the logical numbering is 1-15.

Data Domain Expansion Shelves

FiGurE 2: Front PanEl anD DiSk locationS

Hot-swappable disks  

Physical location: 
Logical numbering:

System Fault LED

Display

Meaning

Blue

Normal operation

Amber

Chassis fault

Yellow

Storage processor fault

White

Do not remove storage processor

1

2

1.1 1.2

3

1.3

2 1.2

3 1.3

1 1.1 

Содержание DATA DOMAIN DD4200

Страница 1: ... rack or cabinet beginning at the bottom to prevent the rack from becoming top heavy Be sure to plan appropriate vertical space to accommodate the 4U controller and 3U for each expansion shelf 4 See the instructions included with the controller and shelf rails 3 Install the controller and expansion shelves in the rack 4 Remove the controller and expansion shelves from the shipping boxes 4 Install ...

Страница 2: ...t or empty Empty SAS SAS BBU NVRAM Figure 3 ES30 Expansion Shelf Expansion shelf disk drive numbering and components Note Physical numbering of the disks is 0 14 while the logical numbering is 1 15 Data Domain Expansion Shelves Figure 2 Front panel and disk locations Hot swappable disks Physical location Logical numbering System Fault LED Display Meaning Blue Normal operation Amber Chassis fault Y...

Страница 3: ...or moving HBA to shelf cables Then add the necessary shelf to shelf cables between shelves in a string as shown in Figure 4 Note that the added shelf will become the highest number shelf in its string requiring one HBA to shelf cable to be moved to connect to its controller A or controller B HOST port The ES30 uses the markings to indicate a HOST port and to indicate an EXP N port Cabling between ...

Страница 4: ...etup Worksheet An installation requires information unique to your site Before starting the installation provide values for the system information listed below 1 A fully qualified host name for the system 2 The DNS domain name 3 Use Table 1 below to enter Ethernet connectivity information 4 A default gateway IP address if no DHCP 5 DNS server IP addresses if no DHCP fill in below Primary Secondary...

Страница 5: ...n integration jsp CIFS The CIFS configuration section in the configuration utility sets up the CIFS clients to allow access to backup on the Data Domain system You also need to set up the CIFS clients to allow access to backup on the Data Domain system For additional configuration information see the specific Data Domain Integration Documentation at https my datadomain com US en integration jsp VT...

Страница 6: ...must be provided to each power cord Voltage 200 240 V Frequency 50 to 60 Hz Site Requirements technical contacts To resolve issues with Data Domain products contact your contracted support provider or visit us online at https my datadomain com corporate contacts 2421 Mission College Blvd Santa Clara CA 95054 866 WE DDUPE 866 933 3873 or 408 980 4800 sales datadomain com Contact Information Copyrig...

Отзывы: