NOTE: 

Refer to the NVRAM Battery Charging Instructions for information on battery 

charge time at initial system installation.

Log into the system with the user name of sysadmin. The password is the 
system’s serial number. At the first login, the CLI configuration utility starts.

You will be prompted to enter the Name, and Domain Name of the system

You will next be prompted to configure the initial IP port. You can choose 
DHCP or enter a static IP address and Net Mask.

You will then be asked to either exit the configuration utility and continue 
configuring the system using the Graphical User Interface, or to continue 
using the CLI configuration utility

Both the CLI configuration utility and GUI configuration wizard contain six 
sections: Licenses, Network, File System, System, CIFS, and NFS. The GUI also 
includes a section to configure VTL.

uSinG tHE cli conFiGuration utility

The list entries in the utility can be comma-separated, space-separated,  
or both.

At each prompt, enter a value, OR

Enter a question mark (?) for more details, OR

Press Enter to accept the value displayed in braces.

Follow the configuration utility instructions for entering appropriate values. 
At the end of each configuration section, you can choose to: Save, Cancel, or 
Retry (restart the input entry as the beginning of the current section).

 

Perform initial System configuration

3

SyStEM SEtuP WorkSHEEt

An installation requires information unique to your site. Before starting the 
installation, provide values for the system information listed below.

1. 

A fully qualified host name for the system:

2. 

The DNS domain name:

3. 

Use Table 1 (below) to enter Ethernet connectivity information.

4. 

A default gateway IP address (if no DHCP):

5. 

DNS server IP addresses (if no DHCP) (fill in below):

Primary

Secondary

Tertiary

6. 

Select the CIFS authentication method:

Workgroup   

Active Directory   

Workgroup name:

Realm name:

Backup user 

name:

Domain admin 

name:

Password:

Password:

7. 

Host name from which to administer the system:

8. 

Administrator’s email address (or admin group alias):

9. 

(Optional) Description of the system’s physical location:

10. 

Mail server (SMTP) host name:

11. 

Time zone name (default is US/Pacific):

12. 

System Controller ID from the License Code document provided in 
the accessory kit. Use this ID to obtain the unique WWPN for this 
controller using the WWPN tool at  

https://my.datadomain.com/US/en/wwpn.jsp

13. 

Record the serial number (SN) found on the back of the chassis, 
center right edge.

14. 

Record all license keys from the license code document provided in 
the accessory kit.

 

Define the Data Domain System information for your Site

2

Ethernet Connectivity

ethMa

eth0x

eth1x

eth2x

eth3x

eth4x

eth5x

Enable

eth0a

eth1a

eth2a

eth3a

eth4a

eth5a

Enable

eth0b

eth1b

eth2b

eth3b

eth4b

eth5b

Enable

eth0c

eth1c

eth2c

eth3c

eth4c

eth5c

Enable

eth0d

eth1d

eth2d

eth3d

eth4d

eth5d

Use DHCP*

IP address (if no DHCP)

Netmask (if no DHCP)

 * 

DHCP is not recommended for production systems

tablE 1:

Содержание DATA DOMAIN DD4200

Страница 1: ... rack or cabinet beginning at the bottom to prevent the rack from becoming top heavy Be sure to plan appropriate vertical space to accommodate the 4U controller and 3U for each expansion shelf 4 See the instructions included with the controller and shelf rails 3 Install the controller and expansion shelves in the rack 4 Remove the controller and expansion shelves from the shipping boxes 4 Install ...

Страница 2: ...t or empty Empty SAS SAS BBU NVRAM Figure 3 ES30 Expansion Shelf Expansion shelf disk drive numbering and components Note Physical numbering of the disks is 0 14 while the logical numbering is 1 15 Data Domain Expansion Shelves Figure 2 Front panel and disk locations Hot swappable disks Physical location Logical numbering System Fault LED Display Meaning Blue Normal operation Amber Chassis fault Y...

Страница 3: ...or moving HBA to shelf cables Then add the necessary shelf to shelf cables between shelves in a string as shown in Figure 4 Note that the added shelf will become the highest number shelf in its string requiring one HBA to shelf cable to be moved to connect to its controller A or controller B HOST port The ES30 uses the markings to indicate a HOST port and to indicate an EXP N port Cabling between ...

Страница 4: ...etup Worksheet An installation requires information unique to your site Before starting the installation provide values for the system information listed below 1 A fully qualified host name for the system 2 The DNS domain name 3 Use Table 1 below to enter Ethernet connectivity information 4 A default gateway IP address if no DHCP 5 DNS server IP addresses if no DHCP fill in below Primary Secondary...

Страница 5: ...n integration jsp CIFS The CIFS configuration section in the configuration utility sets up the CIFS clients to allow access to backup on the Data Domain system You also need to set up the CIFS clients to allow access to backup on the Data Domain system For additional configuration information see the specific Data Domain Integration Documentation at https my datadomain com US en integration jsp VT...

Страница 6: ...must be provided to each power cord Voltage 200 240 V Frequency 50 to 60 Hz Site Requirements technical contacts To resolve issues with Data Domain products contact your contracted support provider or visit us online at https my datadomain com corporate contacts 2421 Mission College Blvd Santa Clara CA 95054 866 WE DDUPE 866 933 3873 or 408 980 4800 sales datadomain com Contact Information Copyrig...

Отзывы: