3-20
EMC CX200-Series DPE2 Hardware Reference
Servicing and Upgrading a CX200-Series DPE2
Installing a Power Supply/System Cooling Module or Blower Module
1. Gently insert the new module into the enclosure, as shown in
Figure 3-15. Be sure the module is completely seated.
Figure 3-15
Installing a Power/Cooling or Blower Module (CX200 Shown)
2. Turn the latch clockwise to secure the module.
The latch holds the module in an established position. It does not pull or
otherwise help to seat the module.
3. If you replaced a power/cooling module, plug the ac power cord
into the new supply, and turn on the power supply. See
Figure 3-16.
Make certain you secure the power cord with the wire bail strain reliefs at
each connector. The strain reliefs prevent the power cord from pulling out of
the connection.
EMC2480
Latch