2-8
Setting Up and Starting a CX700 System
CAUTION
!
Be sure to maintain power and loop integrity when cabling your
storage system. Always connect power supply A, SPS A, SP A,
LCC A(s), and DAE power/cooling module A (on the first DAE)
together in one power/loop configuration. Connect all the B
components together in the same manner.
Making Power Connections - ac Power Source
Note that the CX700 uses retention bails to relieve strain on the ac power
cords and to keep the cords seated in their connectors.
Refer to Figure 2-3 as you connect the ac line cord to the power
supplies.
1. At the back of the cabinet, rotate the retention bail on each power
supply out of the way of the ac connector.
2. Plug the ac line cord into each power supply.
3. Return the retention bail to its original position.
4. Push the cord into the bail loop to hold the cord in position.
Figure 2-3
Connecting the ac Line Cord to the Power Supply
Refer to Figure 2-4 as you connect the ac line cords to your SPS.
EMC1966
Retention
Bail
Power
Switch
Содержание CLARiiON CX700
Страница 4: ...CX700 Hardware Reference iv ...
Страница 8: ...CX700 Hardware Reference viii Contents ...
Страница 18: ...xviii CX700 Hardware Reference Warnings and Cautions ...
Страница 56: ...2 26 CX700 Hardware Reference Setting Up and Starting a CX700 System ...
Страница 74: ...3 18 CX700 Hardware Reference Servicing a CX700 SPE ...
Страница 96: ...A 18 CX700 Hardware Reference Technical Specifications and Operating Limits ...
Страница 104: ...B 8 CX700 Hardware Reference Customer Support ...
Страница 110: ...g 6 CX700 Hardware Reference Glossary ...
Страница 114: ...CX700 Hardware Reference i 4 Index ...