6.3.1.2 EFT operation
test in operation
EUT power v, i
test voltage and time
bar. Black indicates the
actual test time carried
out
In operation mode the
values can be changed
without changing the
programmed test
indicates the status of the actual
test.
when the operator visually detects
a EUT failure, F4 can be pressed
and the status of the test turns to
"failed". Protocol shows " test
failed"
by pressing "Mark" the actual test
parameter will be written in the
protocol and showed on the
display at test end.
The values can be varied as follows within the given ranges:
1. Set the cursor to the parameter to changing
2. With the + or - buttons the values can be changed during operation
3. The protocol will be extended with a remark
6.3.1.3 ESD operation
In the RUN-mode the nominal voltage (V-peak) can be continuously varied using the „+“ and „-“ buttons.
This is very helpful for exactly determining the immunity level of the EUT. The manual change of the
nominal voltage will be noted in the report with a warning see example EFT.
The ESD discharge network must be connected to the outputs HV and Control.
6.3.1.3.1 Contact Discharge
Press "RUN" and contact EUT with the relay tip.
test in operation
EUT power v, i
test voltage and what to
do
discharge mode
5 pulses of 20 are
made
indicates the status of the actual
test
when the operator visually detects
an EUT failure, F4 can be pressed
and the status of the test turns to
"failed". Protocol shows " test
failed"
by pressing "Mark" the actual test
parameter will be written in the
protocol and showed on the
display at test end.
The values can be varied as follows within the given ranges:
1. Set the cursor to the parameter to changing
2. Change with the + or - buttons the values during operation
To stop the running test, press the red RUN button.
Содержание EXTTRA3000 E
Страница 8: ...TRANSIENT3000 8 162...
Страница 102: ...TRANSIENT3000 102 162...
Страница 106: ...TRANSIENT3000 106 162...
Страница 116: ...TRANSIENT 2000 116 162...
Страница 118: ...TRANSIENT 2000 118 162...
Страница 142: ...11BRemote Ports 142 162 All Generators of EMCP can be loaded and demonstrated...
Страница 148: ...12BAppendix and Corrections 148 162 13 1 6 VARIATION Specification IEC 61000 4 11 Ed 2...
Страница 150: ...12BAppendix and Corrections 150 162...
Страница 156: ...14BIndex 156 162...
Страница 158: ...14BIndex 158 162...
Страница 160: ...14BIndex 160 162...
Страница 162: ...14BIndex 162 162...