LOCAL CODES
Install and use log set with care. Follow all local
codes. In the absence of local codes, use the
latest edition of
The National Fuel Gas Code ANSI-
Z223.1/NFPA 54*
.
.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT FEATURES
UNPACKING
CAUTION:Donotremovethe metaldataplatesfrom the
burner pan. The data plates contain important warranty
and safety information.
1. Remove logs, hearth kit, pan materials,
and hardware from carton.
2. Remove all protective packaging applied
to logs and base for shipment.
3. Check appliance for any shipping damage.
If it is damaged call Sure Heat Manufacturing
at 1-800-229-5647 for replacement parts
before returning to dealer.
REMOTE CONTROL SAFETY VALVE/PILOT
This unit is provided with a remote gas control valve
which is connected to a wireless transmitter/rec-
eiver set, allowing safe operation from anywhere
in the room.
Unit is tested and approved to
ANSI Z21.60
as a vented
decorative appliance. It is supplied with the parts and ins-
tructions to convert to propane/LP gas use.
APPROVALS
4
WARNING: The Massachusetts State
Board requires all installations be perform-
ed by a Licensed Plumber or Gas Fitter. Mas-
sachusetts state code requires all vent
dampers be welded open or removed.
CAUTION: Do not remove the data plates
attached to the burner pan. The data plates
contain important warranty and safety informat-
WARNING:Beforeinstallingin a solid fuel
burning
fi
replace, the chimney
fl
ueand
fi
rebox
mustbe cleaned of soot, creosote, ashes and
loose paint by a quali
fi
ed chimneycleaner.
Creosotewillignite if highly heated. Adirty chim -
ney
fl
uemaycreateanddistribute soot within
the house. Inspect chimney
fl
ue for damage.
NOTICE:Installation, service, and repair of this appliance must
be performedbyaquali
fi
edinstaller, service agency, comp-
any or gas supplier, experienced with this type of gas app-
liance. Only factory authorized components should be used,
in accordance with the manufacturer’s instructions and all
codes and requirements of the authority having jurisdiction.
Any modi
fi
cations to this kit, or useofunauthorizedcompon-
ents or accessory items will void the manufacturer’swarranty,
and may result in a hazardous condition.
FLUE OPENING SPECIFICATIONS
Note: This vented appliance must be installed only in a
solid-fuel burning
fi
replace with a working
flue
and con-
structed of noncombustible material.
ion.
INSTALLATION
VENTING SPECIFICATIONS FOR
INSTALLATION
The
fireplace
chimney
flue
and vent must be draft-
ing properly. To check the vent for proper drafting:
Light a tightly rolled newspaper on one end and
place it at the inside front edge of the
fireplace.
Observe the smoke and be sure the vent is prop-
erly drawing it up the chimney. If the smoke spills
out into the room, extinguish the
fl
ame and remove
any obstruction until proper venting is achieved.
The chimney
flue
damper must be
fixed
open to provide a
minimum of 81 sq. in. of free air opening during operation
of this log set. A multipurpose damper clamp is provided
to
fix the damper in position.
The minimum
flue
sizes shown in
Figure 2,
Page 5 are
based on a 6’ chimney height using round pipe. Your
minimum flue size will vary based on input rate and
chimney height. Refer to the
National Fuel Gas Code
ANSI Z223.1/NFPA 54,
Section 6.6, for details.