background image

LIMITED WARRANTY

Sure Heat Mfg. warrants that the components of this appliance are warranted free from

defects in material and workmanshipfor one (1) year from the date of purchase. Sure

Heat Mfg.at its option, willrepair or replace this product or any component of the product

found to be defective during the warranty period. Replacement willbe made with a new

manufactured product or component. If the product isno longer available,replacement may

be made with a similar product of equal value.This warranty does not include transportation 

or shipping costs of any kind. This is your exclusive warranty.

.

This warrantyis validfor the original retailpurchaser from the date of initial retail purchase

and is not transferable.Keep the originalsales receipt. Proof of purchase is required to

obtain warranty parts.

This warranty does not cover normal wear of parts such as scratches and dents of the

 

components or damage resulting from any of the following:

negligent use or misuse of the product, includingexposing the product to chemicalsor cleaning products

• 

not approved by Sure Heat Mfg.
corrosion, rust or discoloring of any kind

• 

use or installationcontraryto specified instructions and applicablebuilding codes, includingheating the

• 

product to temperatures above its rated specifi cations which can cause considerable warping
disassembly, including removal of the product from a built-in installation

• 

damage resulting from accident, alteration, misuse, abuse, hostile environments, or improper installation

• 

repair or alteration

• 

acts of God, such as  fire,flood, hurricanes, and tornadoes

• 

gas cylinders,propane tanks or other fuel deliverysystems,includingconnections to a household fuel

• 

supply
usage other than single-family household use such as commercial or industrial use

• 

minor warping or discoloration of parts, which is normal and not a defect under this warranty

• 

DO NOT RETURN THIS PRODUCT TO THE PLACE OF PURCHASE 

If the appliance does not operate properly , first thoroughly carry out the instructions

provided with the unit to ensure that the appliance is installed correctly and check the

troubleshooting section in this use and care manual.

We recommend you return this warranty registration card so that you can be contacted

should any questions of safety arise that could affect you. The return of the warranty

registration card is not a condition for warranty coverage.

Becauseof continuing product improvement, these specifications are subject to change

without notice.

If you have other questions or need replacement parts contact our

Customer Service Hotline at (800) 229-5647 or

visit our website at www.sureheat.com

Sure Heat Manufacturing, 3140 Moon Station Road, Kennesaw GA, 30144 

RMH-130-OMRCV

Rev2.0  02-2016 

Purchased From: _____________________________________ Date: ____________

Model: ____________________________ Serial Number: ____________________

Name: ______________________________ Phone Number: ___________________

Address: _____________________________________________________________

City: _________________________________ State: ________ ZIP: _____________

Содержание BRO24DBRNL-60

Страница 1: ...phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service...

Страница 2: ...manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its con trols can be dangerous 1 This appliance as supplied is only for use wi...

Страница 3: ...Air for Combustion and Ventilation 10 Do not run log set where combustible materials gasoline and other ammable vapors and liquids are used or stored under dusty conditions 11 Do not burn solid fuel...

Страница 4: ...of soot creosote ashes and loose paint by a quali ed chimneycleaner Creosotewillignite if highly heated Adirty chim ney uemaycreateanddistribute soot within the house Inspect chimney ue for damage NOT...

Страница 5: ...Manufactured Fireplace Masonry Fireplace Damper Clamp Damper Figure 3 Attaching Damper Clamp CONNECTING TO GAS SUPPLY WARNING A quali ed service person must local codes connect log set to gas supply...

Страница 6: ...rom gas supply piping system 2 Cap off open end of gas pipe where equipment shut off valve was connected 3 Pressurize supply piping system by either using com pressed air or opening main gas valve loc...

Страница 7: ...r Inlet Fitting and Pilot Prifice Natural Gas Pilot Orifice Figure 8 Burner Inlet Fittings shown with orifice NATURAL GAS FITTING PROPANE LP GAS FITTING Orifice for Natural Gas Injector for Propane LP...

Страница 8: ...r system is leak free Testing Burner for Leaks 4 When burner is tested and leak free observe individual tongues of ame on burner from ports reaming ports with a modi ed paper clip or other suit able t...

Страница 9: ...log 2 onto raised area of the grate Back Log Stand Offs in place Log Identification Place Cross Log 3 at the left side Place Cross Log 5 atop 3 and 4 at the back left Place Cross Log 4 at the center...

Страница 10: ...right side Place smallest decorative logs 9 and 10 onto the fireplace floor at each end of burner pan Continued 10 8 7 10 9 WARNING Failure to position the parts in accordance with these diagrams or f...

Страница 11: ...rate Place shorter back log 2 onto Back Log Stand Offs in place Back Log Stand Offs 1 2 3 4 5 6 Place Cross Log 3 at the left side Place Cross Log 4 at the center Place Cross Log 5 at the right side P...

Страница 12: ...raised area Log Identification Back Log Stand Offs in place 1 2 3 4 6 7 8 9 on the grate finger left of center Place log 3 onto back left area of the grate perpendicular to log 1 Place log 4 at the fr...

Страница 13: ...the grate Place shorter back log 2 onto raised area of the grate Back Log Stand Offs in place Log Identification Place Cross Log 3 at the left side Place Cross Log 4 at the center left Place Cross Log...

Страница 14: ...LOG PLACEMENT MODEL SH24DBRNL 60 cont Place cross log 7 atop cross log 6 and to front center as shown 14...

Страница 15: ...ack log 3 onto raised area of the grate Log Identification Back Log Stand Offs in place 1 2 Place left front log 2 onto front area of the grate 3 4 5 6 Place Cross Log 4 at the center left Place Y sha...

Страница 16: ...DEL CS30DBRNL 60 Cont Place Cross Log 8 at the top center across logs 5 and 7 Place Cross Log 7 at the center right Place log 8 in front of the set on the fireplace floor Make sure it is in front of t...

Страница 17: ...der water LIGHTING INSTRUCTION 1 STOP Read the safety information on the left side of this page 2 Make sure equipment shutoff valve is fully open 3 Press in and turn control knob clockwise to the OFF...

Страница 18: ...his will drain the battery INSPECTING BURNERS Check pilot ame pattern and burner ame patterns often PILOT FLAME The pilot assembly is factory preset for the proper ame height Alterations may have occu...

Страница 19: ...on 4 Continue holding down con trol knob Repeat igniting op eration until air is removed 5 Adjust pilot flame for ap proximately 2 blue ame 6 Clean pilot see Cleaning and Maintenance above or replace...

Страница 20: ...Preheat flue in very cold weather OBSERVED PROBLEM POSSIBLE CAUSE REMEDY TROUBLESHOOTING Continued Delayed ignition burner 1 Pilot ame needs adjust ing 2 Wrong pilot ori ce for gas type 1 Adjust pilo...

Страница 21: ...DB24 30RNL 60 L 15 18 2 16 13 6 10 17 14 11 7 5 9 12 1 8 3 4 28 20 19 LP Conversion 21 22 23 19 27 25 26 21 24 28 and VMO24RNGA PARTS...

Страница 22: ...ZZ00568A RMH 120 00050 KHH ACT16 Heat Shield RMH 120 RVS304 16 20 18 Pilot Assembly NG RCOZZ00495B 19 Screw Sheet Metal 6 x 1 2 RMH 120 00570 21 Grate Vented 24 Sets 22 SPSCJ00106A Standoff Back Log 2...

Страница 23: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...

Страница 24: ...on misuse abuse hostile environments or improper installation repair or alteration acts of God such as fire flood hurricanes and tornadoes gas cylinders propane tanks or other fuel deliverysystems inc...