background image

Convertible from Natural Gas to Propane/LP  Gas

OWNER'S OPERATION AND INSTALLATION MANUAL

WARNING: If the information in this manual is not

followed exactly, a fire or explosion may result causing

property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any

phone in your building.

• Immediatelycallyourgassupplierfromaneighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire 

department.

— Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

For Use With Log Set Models:

24&30” DBRNL-60 REMOTE CONTROL GAS LOG

VENTED DECORATIVE APPLIANCE

              BURNER SYSTEM

VMO24RNGA (SHOWN)

MO24DBRNL-60

BRO24DBRNL-60

SH24DBRNL-60

CS30DBRNL-60

Listed By

Tested & 

Vented Decorative Appliances

for installation in Solid Fuel 

Burning Fireplaces

C       US

Z21.60 2012

Содержание BRO24DBRNL-60

Страница 1: ...phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service...

Страница 2: ...manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its con trols can be dangerous 1 This appliance as supplied is only for use wi...

Страница 3: ...Air for Combustion and Ventilation 10 Do not run log set where combustible materials gasoline and other ammable vapors and liquids are used or stored under dusty conditions 11 Do not burn solid fuel...

Страница 4: ...of soot creosote ashes and loose paint by a quali ed chimneycleaner Creosotewillignite if highly heated Adirty chim ney uemaycreateanddistribute soot within the house Inspect chimney ue for damage NOT...

Страница 5: ...Manufactured Fireplace Masonry Fireplace Damper Clamp Damper Figure 3 Attaching Damper Clamp CONNECTING TO GAS SUPPLY WARNING A quali ed service person must local codes connect log set to gas supply...

Страница 6: ...rom gas supply piping system 2 Cap off open end of gas pipe where equipment shut off valve was connected 3 Pressurize supply piping system by either using com pressed air or opening main gas valve loc...

Страница 7: ...r Inlet Fitting and Pilot Prifice Natural Gas Pilot Orifice Figure 8 Burner Inlet Fittings shown with orifice NATURAL GAS FITTING PROPANE LP GAS FITTING Orifice for Natural Gas Injector for Propane LP...

Страница 8: ...r system is leak free Testing Burner for Leaks 4 When burner is tested and leak free observe individual tongues of ame on burner from ports reaming ports with a modi ed paper clip or other suit able t...

Страница 9: ...log 2 onto raised area of the grate Back Log Stand Offs in place Log Identification Place Cross Log 3 at the left side Place Cross Log 5 atop 3 and 4 at the back left Place Cross Log 4 at the center...

Страница 10: ...right side Place smallest decorative logs 9 and 10 onto the fireplace floor at each end of burner pan Continued 10 8 7 10 9 WARNING Failure to position the parts in accordance with these diagrams or f...

Страница 11: ...rate Place shorter back log 2 onto Back Log Stand Offs in place Back Log Stand Offs 1 2 3 4 5 6 Place Cross Log 3 at the left side Place Cross Log 4 at the center Place Cross Log 5 at the right side P...

Страница 12: ...raised area Log Identification Back Log Stand Offs in place 1 2 3 4 6 7 8 9 on the grate finger left of center Place log 3 onto back left area of the grate perpendicular to log 1 Place log 4 at the fr...

Страница 13: ...the grate Place shorter back log 2 onto raised area of the grate Back Log Stand Offs in place Log Identification Place Cross Log 3 at the left side Place Cross Log 4 at the center left Place Cross Log...

Страница 14: ...LOG PLACEMENT MODEL SH24DBRNL 60 cont Place cross log 7 atop cross log 6 and to front center as shown 14...

Страница 15: ...ack log 3 onto raised area of the grate Log Identification Back Log Stand Offs in place 1 2 Place left front log 2 onto front area of the grate 3 4 5 6 Place Cross Log 4 at the center left Place Y sha...

Страница 16: ...DEL CS30DBRNL 60 Cont Place Cross Log 8 at the top center across logs 5 and 7 Place Cross Log 7 at the center right Place log 8 in front of the set on the fireplace floor Make sure it is in front of t...

Страница 17: ...der water LIGHTING INSTRUCTION 1 STOP Read the safety information on the left side of this page 2 Make sure equipment shutoff valve is fully open 3 Press in and turn control knob clockwise to the OFF...

Страница 18: ...his will drain the battery INSPECTING BURNERS Check pilot ame pattern and burner ame patterns often PILOT FLAME The pilot assembly is factory preset for the proper ame height Alterations may have occu...

Страница 19: ...on 4 Continue holding down con trol knob Repeat igniting op eration until air is removed 5 Adjust pilot flame for ap proximately 2 blue ame 6 Clean pilot see Cleaning and Maintenance above or replace...

Страница 20: ...Preheat flue in very cold weather OBSERVED PROBLEM POSSIBLE CAUSE REMEDY TROUBLESHOOTING Continued Delayed ignition burner 1 Pilot ame needs adjust ing 2 Wrong pilot ori ce for gas type 1 Adjust pilo...

Страница 21: ...DB24 30RNL 60 L 15 18 2 16 13 6 10 17 14 11 7 5 9 12 1 8 3 4 28 20 19 LP Conversion 21 22 23 19 27 25 26 21 24 28 and VMO24RNGA PARTS...

Страница 22: ...ZZ00568A RMH 120 00050 KHH ACT16 Heat Shield RMH 120 RVS304 16 20 18 Pilot Assembly NG RCOZZ00495B 19 Screw Sheet Metal 6 x 1 2 RMH 120 00570 21 Grate Vented 24 Sets 22 SPSCJ00106A Standoff Back Log 2...

Страница 23: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...

Страница 24: ...on misuse abuse hostile environments or improper installation repair or alteration acts of God such as fire flood hurricanes and tornadoes gas cylinders propane tanks or other fuel deliverysystems inc...