![Embedded Systems LM5p-GSM Скачать руководство пользователя страница 210](http://html1.mh-extra.com/html/embedded-systems/lm5p-gsm/lm5p-gsm_product-manual_2399466210.webp)
210
16.
end
17.
end
)
18.
19.
-- register write callback
20.
mb:setwriteregistercb
(
function
(
register, value
)
21.
if
register
==
0
then
22.
-- send value limited to 0..100
23.
grp.
write
(
'4/1/5'
,
math.min
(
100, value
)
, dt.scale
)
24.
else
25.
alert
(
'register: %d = %d'
, register, value
)
26.
end
27.
end
28.
end
29.
30.
-- server part init
31.
if not
server
then
32.
require
(
'rpc'
)
33.
34.
-- incoming data handler
35.
local
handler
=
function
(
request
)
36.
local
fn, res
37.
38.
fn
=
tostring
(
request.fn
)
39.
40.
if not
mb
[
fn
]
then
41.
return
{
nil
,
'unknown function '
.. fn
}
42.
end
43.
44.
if type
(
request.params
)==
'table'
then
45.
table.insert
(
request.params, 1, mb
)
46.
res
={
mb
[
fn
](
unpack
(
request.params
))}
47.
else
48.
res
={
mb
[
fn
](
mb
)}
49.
end
50.
51.
return
res
52.
end
53.
54.
server
=
rpc.server
(
'127.0.0.1'
,
28002
,
'mbproxy'
, handler, 0.01
)
55.
end
56.
57.
mb:handleslave
()
58.
server:step
()
Example: event script which changes modbus slave coil (address 0)
Must be mapped to a group address with binary value.
Содержание LM5p-GSM
Страница 10: ...10 1 Terminal connection schemes Model ...
Страница 12: ...12 canX connection Powering over 24V terminals ...
Страница 15: ...15 Digital output e g relay contactor ...
Страница 16: ...16 Digital or Analog input e g pushbutton or 0 5V current measurement sensor ...
Страница 17: ...17 Digital input e g pushbutton ...
Страница 18: ...18 1 wire connection ...
Страница 19: ...19 2 Standards supported ...
Страница 22: ...22 3 Insert SIM card and close the holder Close the front cover ...
Страница 36: ...36 ...
Страница 42: ...42 a basic background which can be changed by necessity b foreground which will stay unchanged ...
Страница 48: ...48 ...
Страница 120: ...120 Show logs window show logs in separate window Edit custom JavaScript ...
Страница 151: ...151 Visualization parameters Defines global or local visualization parameter for specific group address ...
Страница 156: ...156 Additional classes additional CSS classes for the element ...
Страница 179: ...179 9 8 KNX connection KNX specific configuration is located in Network KNX connection window General tab ...
Страница 195: ...195 9 23 Running processes System running processes can be seen in Status Running processes window ...
Страница 201: ...201 ...
Страница 221: ...221 Clear binary object value at priority 12 bacnet write 127001 binary value 2305 nil 12 ...
Страница 246: ...246 value event getvalue res value 100 255 grp write 1 1 6 res dt uint8 ...
Страница 277: ...277 ...
Страница 281: ...281 UIO16 16 channel universal input output module When the changes are done for the device it is marked in yellow ...
Страница 282: ...282 Press this button to upload new settings to all modified all devices ...