![Embedded Systems LM5p-GSM Скачать руководство пользователя страница 133](http://html1.mh-extra.com/html/embedded-systems/lm5p-gsm/lm5p-gsm_product-manual_2399466133.webp)
133
6.4.1.
Export logs
Example
Once an hour, make CSV file with all objects logs and send to external FTP server with IP
192.168.1.11, login ‘ftplogin‘, password ‘ftppassword‘.
In
Scripting -> Scheduled
add the script which will run once an hour
Add the following code in Script editor for this particular script.
1.
require
(
'socket.ftp'
)
2.
3.
-- ftp file
4.
ftpfile
=
string.format
(
'ftp://ftplogin:[email protected]/%s.csv'
,
os.date
(
'%Y-%m-
%d_%H-%M'
))
5.
-- get past hour data (3600 seconds)
6.
logtime
=
os.time
()
-
60
*
60
7.
8.
-- list of objects by id
9.
objects
={}
10.
11.
-- objects with logging enabled
12.
query
=
'SELECT address, datatype, name FROM objects WHERE disablelog=0'
13.
for
_, object
in ipairs
(
db:getall
(
query
))
do
14.
objects
[
tonumber
(
object.address
)]={
15.
datatype
=
tonumber
(
object.datatype
)
,
16.
name
=
tostring
(
object.name
or
''
)
,
17.
}
18.
end
19.
Содержание LM5p-GSM
Страница 10: ...10 1 Terminal connection schemes Model ...
Страница 12: ...12 canX connection Powering over 24V terminals ...
Страница 15: ...15 Digital output e g relay contactor ...
Страница 16: ...16 Digital or Analog input e g pushbutton or 0 5V current measurement sensor ...
Страница 17: ...17 Digital input e g pushbutton ...
Страница 18: ...18 1 wire connection ...
Страница 19: ...19 2 Standards supported ...
Страница 22: ...22 3 Insert SIM card and close the holder Close the front cover ...
Страница 36: ...36 ...
Страница 42: ...42 a basic background which can be changed by necessity b foreground which will stay unchanged ...
Страница 48: ...48 ...
Страница 120: ...120 Show logs window show logs in separate window Edit custom JavaScript ...
Страница 151: ...151 Visualization parameters Defines global or local visualization parameter for specific group address ...
Страница 156: ...156 Additional classes additional CSS classes for the element ...
Страница 179: ...179 9 8 KNX connection KNX specific configuration is located in Network KNX connection window General tab ...
Страница 195: ...195 9 23 Running processes System running processes can be seen in Status Running processes window ...
Страница 201: ...201 ...
Страница 221: ...221 Clear binary object value at priority 12 bacnet write 127001 binary value 2305 nil 12 ...
Страница 246: ...246 value event getvalue res value 100 255 grp write 1 1 6 res dt uint8 ...
Страница 277: ...277 ...
Страница 281: ...281 UIO16 16 channel universal input output module When the changes are done for the device it is marked in yellow ...
Страница 282: ...282 Press this button to upload new settings to all modified all devices ...