em@x
26
2.3 Electrical connection
DANGER!
The appliance must be connected to the mains by a qualified
professional, who is familiar with and adheres to the local
requirements and supplementary regulations of your electricity
supplier.
All electrical work must be carried out by a qualified professional. Do
not modify the energy supply. The connection must be carried out in
accordance with the current local and legal regulations
Instructions for the installer (qualified professional)
The appliance is manufactured to work alternating current relevant to the data on
the model plate. The connection cable must be secured in a strain-relief clamp. The
ground wire must be connected to marked clamp of the terminal When the socket
is not accessible for the user
or a fixed electrical connection of the appliance is
required
, an all-pole disconnecting device must be incorporated during installation.
Disconnecting devices are switches with a contact opening distance of at least 3
mm. These include LS-switches, fuses and protectors (EN 30335). Read the
information on the nameplate and the connection diagram before connecting the
appliance to the mains. The electricity supply must be performed via a 16A
automatic cut-out.