60
Troubleshooting
Emagic
EMI 2|6
EMI 2|6. Set Clock Source on the EMI 2|6 to Extern to avoid
this issue.
•
On Windows 98 SE and Windows 2000, there is a technical
limitation that affects digital clock input signals. We there-
fore recommend that the EMI 2|6 is set to Intern for optimal
performance on these operating systems.
•
Mac OS: If the connected digital source uses a sampling rate
that is different to that of the EMI 2|6, resampling occurs in
an attempt to match the rate used by the EMI 2|6. Set Clock
Source on the EMI 2|6 to Extern to avoid this issue.
My DAT recorder doesn’t recognize the EMI 2|6’s
digital signal
•
The S/PDIF signal carries additional information about the
audio material in “Channel Status” messages. As an
example, information about the sampling rate being used.
This information needs to correspond with the actual
sampling rate on some DAT recorders. In this situation, the
sample rate setting of the EMI 2|6 needs to be set to the
appropriate rate, even if the EMI 2|6 is synchronized to an
external source.
Activating CD audio playback via the EMI 2|6
(Windows)
To activate CD audio playback via the EMI 2|6, click in the
checkbox appropriate to the operating system used:
•
Windows ME:
Control Panel > System > Device Manager >
CD ROM > [your device] > Properties
: “Enable digital CD
audio for this CD-ROM device”
•
Windows 98 SE:
Control Panel > Multimedia > CD Music
:
“Enable digital CD audio for this CD-ROM device”
•
Windows 2000:
Control Panel > System > Hardware > Device
Manager > DVD/CD-ROM drives > [yourdevice] > Properties
:
“Enable digital CD audio for this CD-ROM device”