EM-Technik GmbH - Industriestraße 2 - 67133 Maxdorf - Germany
[email protected]
www.em-technik.com
4
• Not suitable as an equipment part with safety function.
• Not
fl
ow reversible. Input and output must not be inter-
changed.
2 Manufacturer’s Speci
fi
cation
2.1 Description
Series 5D110 and 5D210 pressure keeping valves are
used to reduce overpressures caused by work or the sys-
tem. They reduce pressure peaks by opening when the
set pressure is exceeded, thus relieving the system..
2.2 Transport and Storage
• The
fi
tting must be protected against mechanical da-
mage, moisture, dirt and dust. The storage temperatu-
re range is 10 – 40°C.
• Avoid UV radiation and direct sunlight.
• Leave the
fi
tting in its original packaging to ensure the
best possible protection.
• Dispose of the packaging material according to dispo-
sal requirements/environmental protection regulations.
3 Technical Data
3.1 Dimensions 5D110...
G/NPT
L
h
H
H1
H2 D
D2
B
a
a1
d
d1
1/4“
75 15 75 59.5 30 Ø30 Ø55 55
60
40
Ø6.5 Ø 11.5
All data in mm
3.2 Dimensions 5D210...
G
L
H
H1
H2
D
D1
D2
D3
1/4“
55
88
20
17.5
Ø35
Ø12
Ø30
Ø20
All data in mm
Missing dimensions can be found on our homepage un-
der the following link: www.em-technik.com
Special sizes can be asked via [email protected]
3.3 Operating Medium
• Neutral, gaseous and liquid media that do not negati-
vely affect the physical and chemical properties of the
relevant housing and sealing material.
• If you have questions about resistance please contact
em
technik.
• For the maximum permitted operating pressure/tempe-
rature see the pressure guide.
3.4 Pressure Guide
As the temperature rises, the effectiveness of the
fi
tting
falls, as shown by this table.