background image

EM-Technik GmbH - Industriestraße 2 - 67133 Maxdorf - Germany

[email protected]

www.em-technik.com

4

2 Manufacturer’s Specification

2.1 Description

The 4Z series of flow meters offer a wide range of con

-

nection  options  -  rear,  side  and  top  or  bottom.  Special 

and standard measuring tubes are used, which are indi

-

vidually manufactured and calibrated according to cus-

tomer  specification.  Due  to  their  design,  the  4Z  series 

flowmeters are particularly suitable for panel mounting, 

wall mounting and as an inline solution. For measured 

value acquisition, the devices can be supplied with a ring 

initiator on request.

2.2 Transport and Storage

• 

The fitting must be protected against mechanical da

-

mage, moisture, dirt and dust. The storage temperatu

-

re range is 10 – 40°C. 

•  Avoid UV radiation and direct sunlight.
• 

Leave the fitting in its original packaging to ensure the 

best possible protection.

•  Dispose of the packaging material according to dispo-

sal requirements/environmental protection regulations.

3 Technical Data

3.1 Dimensions

article no.

G

~L

~H

B

A

4Z100G0318...

1/8“

~66

~104

23

80

4Z200G0318...

1/8“

~77

~194

34

160

4Z300G0414...

1/4“

~66

~104

23

80

4Z400G0414...

1/4“

~77

~194

34

160

article no.

h

h1

a1

ØD

metering

 tube

4Z100G0318...

20

40

18

4,5

10 x 75

4Z200G0318...

35

90

18

4,5

10 x 150

4Z300G0414...

20

40

18

4,5

10 x 75

4Z400G0414...

35

90

18

4,5

10 x 150

All information in mm

Missing dimensions can be found on our homepage un-

der the following link: www.em-technik.com
Special sizes can be asked via [email protected]

3.2 Operating Medium

• 

Neutral, gaseous and liquid media that do not negati

-

vely affect the physical and chemical properties of the 

relevant housing and sealing material. 

•  If you have questions about resistance please contact 

em

technik.

• 

For the maximum permitted operating pressure/tempe

-

rature see the pressure guide.

3.3 Pressure Guide

As the temperature rises, the effectiveness of the fitting 

falls, as shown by this table.

Material

PP

PVDF

PFA

Pressure Stage

PN 6

PN 6

PN 6

-40°C

75%

75%

-20°C

100%

100%

5°C

100%

100%

100%

20°C

100%

100%

100%

30°C

80%

80%

90%

40°C

70%

70%

85%

50°C

60%

60%

80%

Отзывы: