Page 12 of 25
S-218 User Manual
v1 October 2019
Using a 5mm Allen key, remove the 16 M8 x 20
countersunk socket machine screws on the
rear panel. Ensure that all the threaded fittings
inside the cabinet are still intact and the
threads are clear before proceeding.
Fit each castor to the rear of the cabinet, ensuring
all four bolts are started in their threads before
tightening completely. The Form A (flat) washer
should be in contact with the castor frame, and the
spring washer should be between the flat washer
and the bolt head.
5.5 – Fitting castors
The S-218 is supplied with a set of four tour-grade castors which can be fitted for ease of
movement. The carton should contain:
4pcs 32 x 100mm heavy duty castor
17pcs M8 x 30 hex head set screw
17pcs M8 Form A (flat) washer
17pcs M8 spring washer
Step 1.
Step 2.
M8x30 hex head
set screw
M8 spring washer
M8 Form A washer