3 x AAA

Recommended limit value:
33 TDS/50 µS, if this is 
exceeded then the resin 
needs to be replaced

9 EN

Set limit for
warning

Limit

Reset 
meter

Flow rate

ON/OFF

Total litres treated

Select either
TDS/µS

Automatic quality monitor

Display:

Keys:

Limit warning signal

Operating the combined meter

Changing the batteries

The combined meter is battery-operated. It measures the flow rate in l/min, the total volume in litres and 
the concentration of dissolved minerals, either in microsiemens or TDS. In addition, a limit can be set for the 
maximum concentration of minerals tolerated in the demineralised water (appliance outlet). The limit and 
overall total can both be reset. 

Change  the  batteries  when  the  battery  warning  symbol 
appears or the display is faint or blank. Undo the 4 screws 
on  the  front  and  carefully  open  the  device.  Change  the 
batteries. 3 x AAA.

Each time you touch this key, the boundary value is raised by 6/7 TDS or by 10 µS/cm. Holding down the key 
for 3 seconds resets the boundary value to zero. Programming the boundary value serves as a warning as to 
when the ion exchanger resin is exhausted.

This key can be used to switch at any time between the TDS unit of measurement (Total Dissolved Solids) 
and electrical conductivity. Both are used to measure the concentration of dissolved minerals in the water. 
Most European component manufacturers use the µS/cm unit of measurement (microsiemens).
The water hardness at the outlet of the refill appliance can be calculated using the following rule of thumb:

1 °fH equals approx. 20 µS/cm; 1 °dH equals approx. 35 µS/cm.

1

2

If the ON key is pressed once, the water quality is measured for 10 seconds and compared to the set limit. 
The measured value is shown. If it is above the limit, the LED glows red; if it is below, the LED glows green 
while the measurement is being taken. If required, the measurement can be repeated manually.

Auto mode: 

If the ON key is pressed for a second time, the combined meter begins automatic monitoring. 

The eye symbol appears to indicate that monitoring has been enabled. In auto mode, the meter only takes 
measurements  when  water  is  actually  passing  over  it.  If  the  water  draw-off  is  interrupted,  the  meter 
continues to show the last captured value. While water is being drawn off, the combined meter measures 
the  water  quality  every  40  litres.  If  the  limit  is  exceeded  in  two  successive  measurements,  the  display 
continuously flashes red. This indicates that the ion exchange resin is spent and needs replacing. If the ON 
key is pressed for a third time, the meter exits auto mode.

3

Pressing the reset key for 3 seconds resets the overall total on the meter. This is recommended every time 
the resin is replaced, as it gives a reference point for the remaining capacity of the ion exchange resin.

4

Содержание PUROTAP easy

Страница 1: ...system Installation Function Operation Service fast efficient safe PUROTAP easy Minerals and salts in technical water circulations lead to corrosion and mineral deposits PUROTAP filters aggressive ma...

Страница 2: ......

Страница 3: ...ards The function Connection variations system fill up Connection variations system cleaning Operating the meter Apparatus components Change ion exchanger resin Empty water Repair malfunction 4 5 5 6...

Страница 4: ...capacity e g storage tanks the more lime is introduced withthefill upwater 3 With a hardness of 17 dH and or 30 fH 300g of lime accumulates per m of water This is still approx 100 g for a single fami...

Страница 5: ...of oxygen are tolerated with reducing water salt content When ions are present that can take over the transporting of electrical currents in the water the formation of galvanised elements that can lea...

Страница 6: ...should use the filling apparatus Operating specifications must be adhered to according to this manual Local guidelines are to be followed for the connection between sanitary and heating sys tems The d...

Страница 7: ...ction of the apparatus valve the outlet for the deminera lised water for the heating system is on top on the other side of the safety sieve The apparatus contains a non return valve When the connectio...

Страница 8: ...ch adapter is used instead it is more important that circulation pumps are operating and all valves are open and a good mixture of the system water is possible The apparatus meter indicates if the res...

Страница 9: ...of dissolved minerals in the water Most European component manufacturers use the S cm unit of measurement microsiemens The water hardness at the outlet of the refill appliance can be calculated using...

Страница 10: ...ling 3 has a capacity of 35 m at 1 fH and or 3 20 m at 1 dH The number 20 is used for German hardness grades and this is divided by the water hardness in dH The num ber 35 is used for French hardness...

Страница 11: ...Dispose of the used resin with the catch sack with the household rubbish Drain valve accessories Fresh water a Empty used resin If the content of dissolved solids in treated water increases over 30 TD...

Страница 12: ...Check to make sure that the insert prove is secure during each resin change Check to make sure that the insert prove is secure during each resin change The resin granulate is to be stored in a moist...

Страница 13: ...rost damages in winter we recommend that the water is emptied after use Empty water 1 Loosen the cap on the bottom of the bottle Draining contains a fine sieve so that resin cannot leak out Check that...

Страница 14: ...to conserve the batteries Inmanualmode theONbuttonmuchbepressed for each measurement Alternatively auto mode can be used press the ON button two times then each of the last measuringvaluesarepermanent...

Страница 15: ...ne sieve in the outlet and on the immersion hose regu larly Plastic ring pressed in Stainless steel sieve Immersion hose fine sieve The resin appears to be used faster than calculated There probably i...

Страница 16: ......

Отзывы: