elysator PUROTAP easy Скачать руководство пользователя страница 12

b)  Fill with new resin 

1.  Screw the cap back on the bottom of the resin container for fill-up.

2.  Cut the corner of the resin sack open and fill the resin in.
  Only use original mixed resin.

3.  Screw the head back on, check the o-ring and the sealing face for tightness and cleanliness.

Check to make sure that the insert prove is secure during each resin change.

Check to make sure that the insert prove is secure during each resin change.

The resin granulate is to be stored in a moist place and this is the reason why it is delivered in 
sealed plastic bags. Once the bags are opened, use the resin immediately. The resin can be stored 
in a cool dark place for up to 12 months. There is the risk of capacity loss and bacteria formation if 
now correctly stored.

12 EN

Содержание PUROTAP easy

Страница 1: ...system Installation Function Operation Service fast efficient safe PUROTAP easy Minerals and salts in technical water circulations lead to corrosion and mineral deposits PUROTAP filters aggressive ma...

Страница 2: ......

Страница 3: ...ards The function Connection variations system fill up Connection variations system cleaning Operating the meter Apparatus components Change ion exchanger resin Empty water Repair malfunction 4 5 5 6...

Страница 4: ...capacity e g storage tanks the more lime is introduced withthefill upwater 3 With a hardness of 17 dH and or 30 fH 300g of lime accumulates per m of water This is still approx 100 g for a single fami...

Страница 5: ...of oxygen are tolerated with reducing water salt content When ions are present that can take over the transporting of electrical currents in the water the formation of galvanised elements that can lea...

Страница 6: ...should use the filling apparatus Operating specifications must be adhered to according to this manual Local guidelines are to be followed for the connection between sanitary and heating sys tems The d...

Страница 7: ...ction of the apparatus valve the outlet for the deminera lised water for the heating system is on top on the other side of the safety sieve The apparatus contains a non return valve When the connectio...

Страница 8: ...ch adapter is used instead it is more important that circulation pumps are operating and all valves are open and a good mixture of the system water is possible The apparatus meter indicates if the res...

Страница 9: ...of dissolved minerals in the water Most European component manufacturers use the S cm unit of measurement microsiemens The water hardness at the outlet of the refill appliance can be calculated using...

Страница 10: ...ling 3 has a capacity of 35 m at 1 fH and or 3 20 m at 1 dH The number 20 is used for German hardness grades and this is divided by the water hardness in dH The num ber 35 is used for French hardness...

Страница 11: ...Dispose of the used resin with the catch sack with the household rubbish Drain valve accessories Fresh water a Empty used resin If the content of dissolved solids in treated water increases over 30 TD...

Страница 12: ...Check to make sure that the insert prove is secure during each resin change Check to make sure that the insert prove is secure during each resin change The resin granulate is to be stored in a moist...

Страница 13: ...rost damages in winter we recommend that the water is emptied after use Empty water 1 Loosen the cap on the bottom of the bottle Draining contains a fine sieve so that resin cannot leak out Check that...

Страница 14: ...to conserve the batteries Inmanualmode theONbuttonmuchbepressed for each measurement Alternatively auto mode can be used press the ON button two times then each of the last measuringvaluesarepermanent...

Страница 15: ...ne sieve in the outlet and on the immersion hose regu larly Plastic ring pressed in Stainless steel sieve Immersion hose fine sieve The resin appears to be used faster than calculated There probably i...

Страница 16: ......