![Elvox Vimar RS09 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/elvox/vimar-rs09/vimar-rs09_installation-and-operation-manual_2398003015.webp)
13
RS09/RS09.120
3.1- Wiring for power line, flashing light and electric motor:
3.2- Wiring for 24V outputs:
M
Terminal
number
Description
Function
1-2-3
Power supply line
230/120 Vac power line (1 = phase / 2 = ground wire / 3 = neutral)
4-5
Output for flashing light
Output for flashing light (230/120 Vac max 60 Watt)
6-7-8
Output for powering the electric motor
Output for powering the electric motor (6 = common / 7 = opens / 8 = closes) the
capacitor is connected in terminal 7 and 8 in parallel with the electric motor
9-11
Second radio channel or photo-test output
Second radio channel or photo-test output (can be selected with dip switch 1-3 and 9 =
GND / 11= +24 Vdc max 120 mA)
10-11
Gate movement warning output
Gate movement warning output (10 = GND / 11 = +24 Vdc max 120 mA)
11-12
24 Vdc output
24 Vdc output to power photocells and accessories (11 = GND / 12 = +24 Vdc 300mA)
3.3- Input wiring:
The control panel is supplied with non-jumpered normally closed safety inputs (STOP, FOTO, STPA), add a jumper between the common (COM) and
input you do not intend to use
-
-
+
-
24Vdc output to power photocells and accessories
Second radio channel or photo-test output
Output for viewing gate movement
2CAN AUX +24V GND
Fig. 4
Fig. 5
The sum of the absorptions of the 2CAN, AUX and -VA outputs must not exceed 500 mA
M
M
ELA3
FCAP
COM
FCCH
APRI
COM
APCH
APED
COM
ST
OP
FOT
O
STP
A
230/120 Vac
COM
CH
AP
COM
AP
CH
LAMP
LAMP
N
PE
L
Fig.3
EN