Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 511. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,  
see image below.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

Содержание DB1300

Страница 1: ...Order codes ELUM065 DB1300 DMX Stage Blinder User Manual ...

Страница 2: ... immediately and have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not connect power or switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly st...

Страница 3: ...g the supplied mounting bracket In order to safeguard sufficient ventilation leave 0 5m of free space around the device The housing must never touch surrounding surfaces or objects Always secure the fixture with an appropriate safety wire as a security safety measure Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PAR...

Страница 4: ... type and rating Before replacing the fuse unplug the mains lead To replace the fuse follow the procedure below Step 1 Unscrew the fuse holder on the rear panel with an appropriate screwdriver from the housing anti clockwise Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housing and screw it back in OPERATING DET...

Страница 5: ...not supplied Beam angle 40 x 30 7699 Lux 2m full on DMX channels 1 Dimming auto and master slave modes Dipswitch mode address selection 0 100 dimming Captive power connection fitted with a 13A UK plug 3 Pin XLR input output Convection cooled DB1300 DMX 2 Cell Stage Blinder Specifications DB1300 Stage Blinder Power consumption 1320W Max ambient temperature Ta 45 C Max distance from flammable surfac...

Страница 6: ...g replacing the lamp make sure the fixture is off and disconnected form the mains Keep away from rain and moisture Lamp 2 x Par 36 650W 120V DWE Duty cycle 1 minute full on 3 minutes rest Ta 45 C TC 410 C DMX pinout 1 Ground 2 Signal 3 Signal 09 01 06 07 02 03 05 04 09 Technical specifications 01 Earth point 02 Dipswitches 03 DMX signal indicator 04 3 Pin DMX input 05 3 Pin DMX output 06 Captive p...

Страница 7: ...ure by changing the dipswitches as set out in the table below The starting address is defined as the first channel from which the device will respond to the controller Please make sure that you do not have any overlapping channels in order to control each fixture correctly and independently from any other fixture on the DMX data link If two three or more devices are addressed similarly they will w...

Страница 8: ...92 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274...

Страница 9: ...king DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX add...

Страница 10: ...L89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always...

Страница 11: ...t possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environment...

Страница 12: ...iler to purchase these accessories To keep up to date on the latest accessories and product range additions please visit www prolight co uk Par 36 650W 120V DWE Lamp Order code LAMP91 50mm Professional G Clamp Order code CLAM01A Self Locking Truss Clamp Black Order code GL3017 75cm Safety Wire Order code CLAM03 ...

Отзывы: